Diodes Incorporated DZ23C10-7 for cautious sustaining use

DZ23C10-7 Diodes Incorporated product image

10 V zener pair, 300 mW ceiling, SOT-23-3, -65°C to 150°C operating range

Quick Engineering Summary

FieldValue
ManufacturerDiodes Incorporated
CategoryDiodes - Zener - Arrays
PackageTO-236-3, SC-59, SOT-23-3
Core functionDIODE ZENER ARRAY 10V SOT-23-3
Key electrical rangePower - Max: 300 mW; Temperature Range - Operating: -65°C ~ 150°C; Tolerance: ±5%; Voltage - Zener (Nom) (Vz): 10 V
Reported stock3000 pcs reported — confirm on RFQ

The lifecycle story is the problem, not the silicon

The weak point comes first: DZ23C10-7 carries a direct lifecycle conflict. One field says Active, another says 停止提供, so this is not a clean new-design green light, even with stock at 3000 and Reel - TR packaging in a standard 3,000 package.

The stronger case is narrower. If you already build around a 10 V common-cathode zener pair in SOT-23-3, the form factor and basic electrical identity are clear, and EU RoHS plus MSL 1 (Unlimited) remove two common handling objections. For a fresh platform, clear the lifecycle conflict first.

300 mW is the hard ceiling

It is tight.

The 300 mW rating is a ceiling, not a working point, and it quickly decides whether DZ23C10-7 belongs in a light clamp role or gets ruled out before layout starts.

So the fit is small-signal rail clamping, not energy absorption

And that follows from the rest of the numbers. The nominal zener voltage is 10 V with ±5% tolerance, so DZ23C10-7 fits places where a 10 V clamp window is acceptable and where that spread will not trip a threshold too early or too late. The 1 Pair Common Cathode configuration also matters: it suits dual-node protection or paired references that want a shared cathode node, and it does not help if your schematic expects isolated single zeners.

Package and mounting keep the use case compact. SOT-23-3, surface mount, and the TO-236-3 / SC-59 footprint class point to dense board work, not leaded service hardware or anything that needs generous thermal mass. The operating range of -65°C to 150°C settles the environmental ceiling, but it does not settle thermal design because the listing stops short of the thermal resistance and derating information that would show how much ambient headroom the 300 mW limit really leaves.

10 V and 15 Ohms decide whether the clamp is usable

10 V is the nominal zener point, and 15 Ohms is the maximum Zzt. Those two numbers decide whether DZ23C10-7 can do the job.

Start with the 10 V value. It is the nominal clamp target, not a promise that every event lands exactly there, and the ±5% tolerance means the threshold window is only loosely centered. That works for general rail limiting and simple node protection, but it can be the wrong part when the protected circuit has little margin around its absolute maximum or turn-on threshold.

Then the 15 Ohms maximum impedance sets how soft the zener behavior may be under test conditions. Higher zener impedance means more voltage movement as current changes, so the decision here is about clamp stiffness, not just nominal voltage. If your circuit only needs a broad 10 V ceiling, DZ23C10-7 may be enough. If the protected node is sensitive to overshoot during current transients, this listing does not give the dynamic picture you would want.

The 300 mW maximum belongs in the same conversation. It is a dissipation ceiling for the array, not permission to hold the device at that load, and without a forward-voltage figure at a stated If, a reverse-leakage figure at a stated Vr, or any surge rating, you cannot turn this page into a pulse-energy answer. That missing detail is exactly where field failures start when a small zener array gets asked to absorb more than a trim clamp should.

What the listing still does not tell you

Wrong for surge-heavy protection first. Right for it only after the missing basics show up.

The gaps are specific. There is no reverse leakage value at any Vr, no forward voltage at any If, no thermal resistance, and no derating curve. For DZ23C10-7, those are not extras; they decide standby loss, fault behavior, and how close the part can sit to its 300 mW ceiling in real ambient conditions. A pin-level drawing is also absent here, which matters because common-cathode arrays are easy to misread when a footprint gets reused across similar SOT-23-3 parts.

View the Win-Source product page for DZ23C10-7.

Key Takeaways for Engineers & Buyers

  • Resolve the Active versus 停止提供 lifecycle conflict before adding DZ23C10-7 to a new BOM.
  • Keep DZ23C10-7 on reel builds; packaging is Reel - TR with a 3,000 standard package.
  • Treat 300 mW as the dissipation ceiling and 15 Ohms Zzt as the clamp-stiffness limit.