Vishay DZ23C18-E3-18 active 18 V zener array

DZ23C18-E3-18 Vishay product image

18 V nominal zener, 300 mW ceiling, SOT-23 common-cathode pair, -55°C to 150°C operating range

Quick Engineering Summary

FieldValue
ManufacturerVishay
CategoryDiodes - Zener - Arrays
PackageSOT-23
Core functionDIODE ZENER ARRAY 18V SOT-23-3
Key electrical rangeCurrent - Reverse Leakage @ Vr: 100nA @ 14V; Maximum Power Dissipation: 300mW; Supply and Demand Status: Balance; Temperature Range - Operating: -55°C to 150°C
Reported stock1 pcs reported — confirm on RFQ

Not for power dumping; fine for compact dual clamps

Wrong part for any rail clamp that has to absorb much energy. The 300mW maximum power dissipation is a ceiling, and the SOT-23 body leaves little thermal margin.

It does fit a compact dual-zener job: 1 Pair Common Cathode, SMD, 18V nominal, Active, and EU RoHS compliant.

Buy it only against a real build

Stock is tight.

The part is active, but the listed quantity is 1 and the package format is Reel - TR. That combination does not support casual prototype demand or an unplanned line stop. Place it against a scheduled need, or hold release until supply is lined up in the packaging your feeder expects.

18V decides the rail, but 300mW and 50 Ohm decide the pain

18V is the first number that matters. It sets the nominal clamp level for DZ23C18-E3-18, and with ±5% tolerance it also says this is not the part to choose when the protected node has very little voltage headroom.

The harder limit is 300mW maximum power dissipation. That is a ceiling, not a working point, and it rules out using this device as a casual sink for repeated surge energy or any sustained overvoltage condition. If the fault lingers, the design fails here first, not at the nominal zener value.

Then there is 50 Ohm maximum Zzt. For a zener array, that tells you the clamp shifts under load; the nominal 18V does not stay put once current rises, so the downstream node can still see overshoot during a transient. That puts DZ23C18-E3-18 in light protection duty rather than a precision reference role.

At the low-current end, 100nA @ 14V keeps reverse loss low below the nominal zener region, so high-impedance sensing nodes are more plausible here than with a leakier clamp. It helps, but it does not change the dissipation ceiling.

The package and topology narrow the use case fast

And that use case is narrow. DZ23C18-E3-18 is a zener array in SOT-23 with 1 Pair Common Cathode, so it fits where two lines need the same reference node and board area is scarce.

That points to compact interface protection, bias limiting, or dual-node clamping around an 18V threshold on a board that already wants SOT-23 assembly. It does not suit single-diode drop-in use, and it does not suit applications where the common-node orientation is backwards for the protection scheme. Get that topology wrong and the part is useless before any electrical limit is tested.

The missing curves are what would close the call

100nA @ 14V is useful, but the missing items are the ones that finish the decision. The forward-voltage entry is blank, so there is no listed Vf behavior for forward-conduction cases. There is no thermal resistance, no derating curve, no pinout drawing, and no transient or surge figure such as IFSM.

Those gaps matter more than another line of catalog detail. The derating curve sets ambient headroom, the thermal data sets how close 300mW can be approached on a real board, and the pinout drawing is still needed to lock the common-cathode routing.

View the Win-Source product page for DZ23C18-E3-18.

Key Takeaways for Engineers & Buyers

  • Treat 300 mW as the dissipation ceiling; don't size DZ23C18-E3-18 from the 18 V nominal alone.
  • Match the clamp topology to the 1 Pair Common Cathode configuration before layout starts.
  • Book reel supply early; stock is 1 while DZ23C18-E3-18 is listed in Reel - TR.