18 V nominal, 200 mW ceiling, SC-90/SOD-323F SMD package, ±5% tolerance
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Diodes - Zener - Single |
| Package | SC-90, SOD-323F |
| Core function | DIODE ZENER 18V 200MW SMINI2 |
| Key electrical range | Current - Reverse Leakage at Vr: 50nA at 13V; Maximum Power: 200mW; Supply and Demand Status: Balance; Tolerance: ±5% |
| Reported stock | 9330 pcs reported — confirm on RFQ |
200mW is the first limit that decides this part
200mW sets the tone immediately. It keeps this device in signal-level clamp and reference duty, not in anything expected to absorb repeated fault energy, because the 18V zener value tells you where regulation starts nominally while the power limit tells you how little abuse the package can take before the package, not the schematic, becomes the real constraint.
The package callouts back that up. SC-90, SOD-323F, and SMini2-F5-B point to a very small SMD body, so this fits compact rails and light protection paths rather than a general-purpose suppressor. EU RoHS is clear. Lifecycle is not: one field says Active and another says 停止提供, which is enough to keep DZ2J18000L in sustaining designs instead of making it the anchor of a new platform.
That 18V mark does not close the clamp question by itself
And the ±5% tolerance is the reason. An 18V nominal zener with that spread can work on a loose housekeeping rail and still miss the mark where the protected node has little headroom above the intended clamp point. Place DZ2J18000L only where that tolerance band still leaves real circuit margin.
The other ceiling worth keeping in view is the forward rating: 1V at 10mA. That is a stated forward-drop limit at a stated current, not a target operating point, and it matters as soon as the fault case includes forward conduction.
The weak point is lifecycle clarity, not the electrical listing
The weak point is lifecycle clarity, not the electrical listing. Electrically, the picture is coherent: 18V nominal, 60 Ohms maximum zener impedance, and 50nA at 13V for reverse leakage all fit a small zener meant for light-load regulation or clamp service where leakage matters and dynamic stiffness only needs to be moderate.
That 60 Ohms maximum is the number that keeps expectations honest. It does not rule the part out for bias rails, detector inputs, or housekeeping nodes, but it does rule out treating it like a tight shunt reference under changing current. If the rail shifts with load steps, zener impedance is part of the reason, and the clamp point can wander more than the schematic suggests.
The 50nA at 13V figure is the cleaner part of the story. For circuits that sit near the knee for long periods, low reverse leakage helps keep standby error and bleed current down. But the listing still leaves out the operating temperature range, so there is no temperature-backed statement here about leakage drift or zener stability across the ambient range the product may actually see.
Can you keep a running line on it?
Can you keep a running line on it? Yes, with caution. There are 9330 in stock, packaging is Reel, manufacturer pack quantity is 1, and supply-demand status is Balance, so the near-term issue is not pack format. It is lifecycle ambiguity.
One field says Active. Another says 停止提供. Use available stock to support existing production, then confirm manufacturer status through normal channels before the next build window. MSL 1 (Unlimited) helps on floor handling, but it does not answer the sourcing question.
What the listing still does not answer
The constraint is missing review-critical detail. Operating temperature range, thermal resistance, pinout or package drawing, surge or overload behavior, and the zener curve beyond the single 18V nominal point are not here.
View the Win-Source product page for DZ2J18000L.
Key Takeaways for Engineers & Buyers
- Treat 200mW as the dissipation ceiling and check board heat spreading around the SC-90, SOD-323F footprint.
- Hold the clamp target against the 18V nominal and ±5% tolerance before dropping DZ2J18000L into a tight rail limit.
- For running builds, reserve stock against the 9330 on hand because lifecycle signals conflict.