4.31 V, 200 mW, ±15%, SMini4-F3-B, -40°C to 85°C: built for light clamp duty
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Diodes - Zener - Arrays |
| Package | SMini4-F3-B |
| Core function | DIODE ZENER ARRAY 4. |
| Key electrical range | Operating Temperature Range: -40°C ~ 85°C; Supply and Demand Status: Limited |
| Reported stock | 1 pcs reported — confirm on RFQ |
Not for new platforms; fine for small clamp jobs
Wrong for a fresh platform. The conflict between Active and 停止提供 is enough to keep DZ4J043K0R out of new design-in before supply risk even enters the discussion.
It still has a clear place in existing builds that already use this footprint and clamp level: two independent 4.31 V zener elements in SMini4-F3-B, surface mount. The ±15% tolerance rules out any precision-reference reading, while the -40°C to 85°C operating range keeps it in ordinary commercial and industrial ambient bands rather than harsher corners. EU RoHS is listed, and MSL 1 (Unlimited) removes one handling concern.
Can you actually buy enough of it?
Can you get enough parts to support the line? Stock quantity is 1, supply and demand status is Limited, and the package is Reel - TR with quantity per package 3000.
That combination sets the buying posture. Don’t drop DZ4J043K0R onto a live BOM and assume you can top up later; use it where the line already depends on this exact array, then plan around full reels instead of loose replenishment. The open-market fake threat is listed at 43 pct., so spot buys are a bad bet when exposure is high.
200 mW is the ceiling that matters
200 mW is the ceiling that matters. With 4.31 V nominal zener voltage, 130 Ohms maximum Zzt, and 1 V at 10 mA forward, this is a light clamp, not open-ended protection.
The missing curves are what would close the call
The weak point is what is missing, not what is stated.
A pinout or drawing for the 4-SMD, flat lead body would remove the most immediate risk, because array parts fail fast when orientation or channel assignment is wrong. Thermal detail is missing too: a derating curve or thermal resistance would tell you how much of that 200 mW ceiling survives real ambient conditions and board copper in SMini4-F3-B, instead of leaving the number as a bare limit with no context for use.
For protection work, the absent surge current figure is just as important. Without it, there is no clean way to judge whether a short pulse is routine stress or the start of a field return problem. The only reverse leakage point given is 10 µA at 1 V, and that says very little about clamp sharpness near 4.31 V. That missing zener curve is the difference between a part that merely sits on the rail and one that actually catches the event you care about.
View the Win-Source product page for DZ4J043K0R.
Key Takeaways for Engineers & Buyers
- Treat 200 mW as the dissipation ceiling for each 4.31 V zener path before assigning clamp duty.
- Lock reel planning early: package is TR and quantity per package is 3000, while stock quantity is 1.
- Do not clear new builds on Active alone; the lifecycle conflict around DZ4J043K0R needs a sustaining-only decision.