39 V nominal, 200 mW ceiling, 2 independent zeners in SMini4-F3-B, -40°C to 85°C operating range
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Panasonic |
| Category | Diodes - Zener - Arrays |
| Package | Tape & Reel |
| Core function | DIODE ZENER ARRAY 39V SMINI4F3-B |
| Key electrical range | Current - Reverse Leakage @ Vr: 50 nA @ 30 V; Power - Max: 200 mW; Temperature Range - Operating: -40°C ~ 85°C; Tolerance: ±5% |
| Reported stock | 1 pcs reported — confirm on RFQ |
Wrong for new platforms, still usable in a running line
Not for a fresh design. DZ4J390K0R is marked Discontinued, and the lifecycle conflict is only between EOL and Discontinued, not between bad news and good news.
Its remaining use case is narrow: keeping an existing board alive when the land pattern and clamp point are already locked to a 4-SMD, flat-lead SMini4-F3-B footprint with two independent 39 V zeners. Supply is the real problem. Stock is 1, so even sustaining use calls for an immediate line-by-line check of open demand, and EU RoHS status is still unresolved because one field says compliant while another says non-compliant.
The power ceiling is the first limit that bites
The constraint is 200 mW maximum. It is a ceiling, not a working point, and it sets the limit on surge or continuous clamp duty for each zener position.
The fit is board-level rail clamping, not heavy transient work
Not for heavy transients.
This is a compact dual clamp, not a broad-shouldered protection part. The package and function point it toward dense board-level rail or signal protection where two separate clamp nodes need to fit in one small surface-mount footprint, and the 39 V zener value with ±5% tolerance is enough to tell you whether the clamp window is even in range.
Past that, the limits show up quickly. The 300 Ohms maximum Zzt says the knee is not especially stiff, so a circuit that depends on tight clamping has to account for a node that can still rise more than the rest of the design may tolerate under stress. The forward path matters too: 1 V maximum at 10 mA sets the ceiling for forward conduction when polarity can reverse, but it says nothing about behavior above that listed current.
Temperature closes off more use cases. The operating range is -40°C to 85°C, acceptable for ordinary indoor and light industrial electronics, but a weak fit once the board sits near hotter power parts or inside an enclosure that has already spent most of its ambient budget. Nothing in these numbers points to heavy transient work, and nothing here expands the role beyond modest board-level clamping.
1 piece on hand changes the buying decision
1 piece is not supply. With DZ4J390K0R already discontinued and shipped in 3,000 pcs tape and reel, the practical move is to reserve any remaining stock only for existing production that cannot yet absorb a footprint or qualification change.
Documentation is the other problem. The RoHS record is contradictory, so this part should not pass a compliance gate on assumption.
What the listing still does not tell you
39 V is not enough.
The missing items are the ones that decide whether the part survives real transients and whether the board can shed the heat. There is no thermal resistance, so the 200 mW ceiling cannot be tied to board temperature rise. There is no surge or overload figure such as IFSM, so short-event survivability remains open. There is no junction capacitance, which matters on fast or high-impedance nodes. There is also no pinout or package drawing here, and for a 2 independent array that omission blocks a clean footprint and net assignment check.
View the Win-Source product page for DZ4J390K0R.
Key Takeaways for Engineers & Buyers
- Block new BOM releases on DZ4J390K0R; lifecycle is Discontinued.
- Check clamp budget against the 200 mW ceiling before approving any sustaining build.
- Resolve the RoHS conflict before shipment; one field says compliant and another says non-compliant.