20 AWG (0.75mm²), 14.00mm overall, 8.00mm pin, DIN single-wire insulated ferrule
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Category | Terminal Blocks - Wire Ferrules |
| Package | Box |
| Core function | INSULATED CABLE END |
| Key electrical range | Supply and Demand Status: Shortage |
| Reported stock | 1 pcs reported — confirm on RFQ |
Active part, but the buy constraint is immediate
And that is the split on Schneider Electric DZ5CE007D: lifecycle is not the problem, availability is. The part is listed Active with low lifecycle risk and no conflicting status signals, so there is no lifecycle reason to keep it out of a new build. EU RoHS is compliant, removing one routine paperwork objection, but the practical limit sits elsewhere.
Supply is the issue. Stock is listed as 1, and the supply-and-demand status is Shortage. For a ferrule, that matters more than it would for a niche service part because these are consumed in volume, and line stoppages happen one termination at a time rather than one controller at a time. If DZ5CE007D is already on a running line, secure the quantity you need now; if this is a fresh release, do not assume the same channel will support later top-up demand without delay.
The fit decision is mostly mechanical
It fits or it doesn’t.
This is a single-wire, insulated DIN ferrule sized for 20 AWG (0.75mm²). That settles conductor size, not terminal compatibility.
14.00mm overall and 8.00mm pin decide the termination
14.00mm overall length and 8.00mm pin length decide whether this ferrule belongs in the harness drawing or gets rejected before first article.
The 20 AWG (0.75mm²) size tells you what conductor it is meant to terminate. The 8.00mm pin tells you how much metal is presented to the terminal. The 14.00mm overall length tells you how much room the insulated ferrule body takes once the wire is dressed.
Those are fit numbers, not performance margins. They do not tell you insertion force, pullout behavior, or current rise in a crowded terminal block, and treating them as if they did is how a clean bench build turns into rework on the line. The DIN style and single-wire construction place DZ5CE007D in control-panel and cabinet wiring where ferrule geometry is standardized around the terminal hardware, not in applications that need multi-wire entry or unusual conductor packing.
What the listing still doesn’t answer
Can the line keep running on this exact item?
From listed stock alone, no.
The remaining gaps are technical: no drawing, no pin or barrel diameter detail, no insulation material callout, and no crimp-tool or crimp-profile information. For DZ5CE007D, those are the missing pieces that close the review, because ferrules fail in practice on geometry and process control long before anyone argues about color or box packaging.
View the Win-Source product page for DZ5CE007D.
Key Takeaways for Engineers & Buyers
- Match the wire to 20 AWG (0.75mm²); that size callout is the fit decision.
- Check terminal entry depth against the 8.00mm pin before releasing the crimp spec.
- Place an order only against demand; stock is 1 and status is Shortage.