18 AWG (1.00mm²), 18.00mm overall, 12.00mm pin, insulated single-wire ferrule under shortage
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Schneider Electric |
| Category | Terminal Blocks - Wire Ferrules |
| Package | Box |
| Core function | CABLE END MARKERS DZ5+OPTIONS |
| Key electrical range | Supply and Demand Status: Shortage |
| Reported stock | 1220 pcs reported — confirm on RFQ |
Can you put DZ5CE010L12 into a new build?
Can this go into a new build? Yes, when the need is specific: an insulated single-wire ferrule for 18 AWG (1.00mm²) conductors with 18.00mm overall length and 12.00mm pin length.
That answers the basic fit question for control wiring and terminal prep. It does not answer electrical ratings the listing does not show.
DZ5CE010L12 is Active, and EU RoHS is covered in one line. The catch is supply, not status. The same record also says Shortage, so it fits a new design-in only when you can buy the line item early and keep it tied to a known 18 AWG termination geometry.
The numbers here are fit limits, not a wiring free-for-all
The constraint is conductor and terminal geometry. The 18 AWG (1.00mm²) size is the main decision point because it defines the wire this ferrule is meant to terminate and rules out treating it as a general-purpose sleeve across adjacent wire sizes. Get that wrong and the failure mode is plain: poor crimp fill on one side, insertion trouble on the other.
The 12.00mm pin length is a limit too. It tells you how much metal enters the terminal, but it does not tell you contact resistance, pull-out force, or current handling in the finished connection, all of which still depend on the mating terminal system and are not listed here.
Then there is the 18.00mm overall length. That number decides clearance in dense terminal strips, marker channels, and wire ducts; it does not settle bend radius or strain relief. Because DZ5CE010L12 is insulated and single-wire, the clean fit is panel wiring where one conductor per termination is the intent. Using it for doubled conductors is an unsupported assumption, and nothing in the listing extends it that far.
Wrong for electrical signoff, right for controlled panel wiring
Wrong for any build that needs voltage, current, temperature, or flammability limits on the ferrule itself. Those numbers are absent.
Right for insulated single-wire termination on 18 AWG (1.00mm²) conductors, especially where red identification and a boxed accessory line from Schneider Electric already match the rest of the panel bill.
1220 pieces do not cancel a shortage flag
1220 pieces matter, but they do not erase the demand signal.
The buy-side issue on DZ5CE010L12 is straightforward: the listing shows Box packaging, stock quantity 1220, and Supply and Demand Status as Shortage. That combination supports securing the requirement for existing builds and near-term releases now rather than assuming this ferrule will stay easy to replenish because the lifecycle is Active.
The missing details are just as limiting. There is no pinout or drawing beyond the two length fields, no temperature rating, no voltage or current rating, and no crimp or pull-out performance data. For DZ5CE010L12, those are the gaps that keep this from closing a real release decision.
View the Win-Source product page for DZ5CE010L12.
Key Takeaways for Engineers & Buyers
- Match DZ5CE010L12 only to 18 AWG (1.00mm²) conductors before release.
- Check terminal depth against the 12.00mm pin length and 18.00mm overall length.
- Cover the flagged Shortage now; 1220 pieces on hand is the number to plan around.