Diodes Incorporated DZT2907A-13 for new design-in

DZT2907A-13 Diodes Incorporated product image DZT2907A-13 Diodes Incorporated product image

60V VCEO, 600mA collector ceiling, 1W dissipation limit, SOT-223 package, -55°C to 150°C TJ

Quick Engineering Summary

FieldValue
ManufacturerDiodes Incorporated
CategoryTransistors (BJT) - Single
PackageSOT-223
Core functionTRANS PNP 60V 0.
Key electrical rangeCollector Cut-off Current(Max): 10nA (ICBO); Frequency - Transition: 200MHz; Maximum Current Collector: 600mA; Maximum Power Dissipation: 1W
Reported stock334000 pcs reported — confirm on RFQ

The real limit here is heat, not headline current

The numbers create a thermal constraint first. A 600mA collector ceiling looks workable until the 1W dissipation limit and 1.6V VCE(sat) max at 50mA, 500mA start consuming margin, so this device works for new design-in only when those figures are treated as ceilings rather than a promise that every listed maximum can be used at once.

The 60V VCEO ceiling settles rail compatibility cleanly. It does not describe switching stress behavior, because this listing gives no switching waveform, no safe-operating-area view, and no thermal resistance. The -55°C to 150°C operating range is a junction limit, not ambient permission.

Not for blind high-current switching

Blind high-current switching is the wrong use case. The listing gives a 600mA maximum collector current, but it also gives 1.6V max VCE(sat) at 50mA, 500mA and only 1W maximum power dissipation, so the current figure alone does not close the thermal budget; get that wrong, and the package becomes the failure point before the schematic does.

A better fit is board-level PNP duty in SOT-223 where a 60V collector-emitter breakdown ceiling matters and an active part is preferable to a sourcing gamble. The minimum hFE of 100 at 150mA, 10V helps with bias planning at that test point, but it is not a blanket gain guarantee across the full load range. The 200MHz transition frequency shows this is not limited to slow, low-frequency work, yet it still leaves storage time and switching loss unanswered.

For line-powered control, load gating, or general-purpose analog and switching stages that stay inside the 60V, 600mA, and 1W ceilings, DZT2907A-13 is a sensible fit. For designs that depend on low saturation loss, pulse stress handling, or fast turn-off behavior, the missing detail here is the deciding issue.

334000 pieces changes the buying decision

334000 pieces is enough to make this a real production option. With Active lifecycle status and Reel - TR packaging alongside that stock position, the practical move is to qualify it in the package form the line will actually place.

The stock figure supports a running build today, but the decision still turns on whether SOT-223 and reel handling match the assembly flow. EU RoHS is listed, removing one routine compliance objection.

The missing data is the real review stopper

Some gaps are decisive.

Thermal resistance, pinout or package drawing, and switching detail such as storage or recovery behavior are still missing. Without them, you cannot close board temperature, land pattern confidence, or switching stress.

View the Win-Source product page for DZT2907A-13.

Key Takeaways for Engineers & Buyers

  • Keep DZT2907A-13 below the 60V VCEO ceiling; that number closes rail compatibility, not switching behavior.
  • Budget conduction loss around the 1.6V VCE(sat) max at 50mA and 500mA before treating 600mA as usable load current.
  • Lock reel handling for DZT2907A-13 now if the build is volume; packaging is Reel - TR and stock is 334000.