50VA, 120V, 240V primary, 24V secondary, chassis mount, 101.30mm x 76.50mm x 69.10mm max
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | SolaHD |
| Category | Power Transformers |
| Package | Box |
| Core function | PWR XFMR LAMINATED 50VA CHAS MT |
| Key electrical range | Power - Max: 50VA; Supply and Demand Status: Shortage; Voltage - Primary: 120V, 240V; Voltage - Secondary (Full Load): 24V |
| Reported stock | 3 pcs reported — confirm on RFQ |
Stock is the weak point; the electrical fit is straightforward
The weak point comes first: only 3 are on hand, and the supply status is Shortage. That's the real reason to hesitate, not lifecycle, which is listed Active.
Electrically, the fit is easy to read. A 120V, 240V primary with dual, multiple taps gives line-voltage flexibility, while the 24V secondary and 50VA ceiling define the output class you can design around. That ceiling does not settle continuous thermal headroom in your enclosure, and 24V is the listed full-load secondary rather than a statement about no-load behavior. E050E is usable for a new chassis-mounted mains transformer design, but only if you can work within a short buy window and an unresolved EU RoHS conflict.
The hard limit is physical volume
Physical volume is the gate: 101.30mm L x 76.50mm W with 69.10mm max height. If that space is not available in the chassis, E050E is out before the winding options matter.
Wrong for dense boards, right for line-powered chassis builds
Wrong for compact board-level power. Right for line-powered chassis builds.
E050E is a laminated-core, chassis-mount transformer with solder and quick-connect terminations, so it belongs in equipment that already expects a mounted mains transformer and has room for wiring, standoffs, and service access.
That package and mounting style fit cabinet or panel hardware where a 24V secondary is needed from a 120V or 240V input and where a center tap is actually used. The dual, multiple-tap primary is the useful detail because it decides whether one transformer can cover both input rails without changing the mechanical design. The single secondary keeps the use case narrower: if your design needs multiple isolated secondaries, E050E does not meet that requirement.
The 50VA rating is a ceiling, not a target load point, and it tells you only the class of load the transformer can support. It does not settle temperature rise inside a sealed enclosure, inrush behavior at turn-on, or how much margin remains once ambient climbs, all of which can turn a workable electrical choice into a hot box, nuisance fuse action, or a transformer that runs louder and hotter than the mechanical team expected.
50VA is not enough information by itself
50VA is the headline figure, but it is not the missing one. What closes the review is a pinout or lead identification, a mechanical drawing beyond overall size, and the isolation voltage listing, because those decide wiring, safety spacing, and chassis layout.
The listing also does not carry output current, weight, or a temperature-rise or thermal limit figure. Without those, E050E can be placed mechanically and selected topologically, but thermal and protection details remain open.
View the Win-Source product page for E050E.
Key Takeaways for Engineers & Buyers
- Reserve E050E only for builds that need a 24V secondary and center tap.
- Check enclosure clearance against 101.30mm x 76.50mm footprint and 69.10mm max height.
- Resolve the RoHS conflict before release: one field says compliant, another says non-compliant.