SolaHD E050TC active, but buy only for committed builds

E050TC SolaHD product image

50VA, chassis mount, 110.70mm x 86.10mm, 75.20mm max height: fit and availability decide E050TC.

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 50VA CHAS MT
Key electrical rangePower - Max: 50VA; Supply and Demand Status: Shortage
Reported stock5 pcs reported — confirm on RFQ

50VA is enough to place it, not enough to finish the design

50VA is the deciding number. It puts E050TC in the mains-frequency power-transformer class, not in signal duty and not in the kind of low-power corner where a small part can disappear inside the enclosure.

That 50VA figure is a ceiling, not a working point, and it still leaves the electrical match unresolved because the listing gives no primary voltage, no secondary voltage, no output current, and no isolation voltage. E050TC is suitable for new design-in only when the mechanical format and transformer class already fit the build, and when those missing electrical basics are cleared from the datasheet. Lifecycle is Active, but the compliance picture is not clean: one field says RoHS Compliant and another says RoHS Non-Compliant.

The mechanical envelope is what will reject it first

So the next filter is physical, not theoretical. Chassis Mount, 110.70mm L x 86.10mm W, and 75.20mm seated height place E050TC squarely in enclosure-mounted iron, where clearance, mounting area, and wiring access settle the question before anyone gets far into tap selection.

The laminated core construction points the same way. This part belongs in equipment that already expects a conventional mains transformer and has room for solder or quick-connect terminations. It does not belong in a compact board-only supply, and the lack of a center tap rules out designs that were counting on that topology without wiring changes. Space decides this.

5 pieces means this is not a casual line item

5 pieces is the constraint that matters now. E050TC is marked Shortage and packaged in Bulk, so it belongs on committed builds, not on a broad AVL.

What the listing still doesn't answer

What would stop a release first? Electrical identity. E050TC is described as single primary with multiple taps and single secondary with multiple taps, but the actual tap voltages are absent, so you still cannot match it to the mains input range or the downstream rail plan.

The rest of the missing data is just as concrete. There is no primary voltage, no secondary voltage at full load, no maximum output current, and no isolation voltage. Those numbers decide safety spacing, fuse strategy, and whether the secondary can carry the intended load without forcing a redesign after first article build. The listing also gives no weight or drawing, which matters because a chassis-mounted laminated part this size can create mounting and shipping surprises if the bracketry was sized from footprint alone.

View the Win-Source product page for E050TC.

Key Takeaways for Engineers & Buyers

  • Reserve E050TC only for builds that truly need 50VA and chassis mounting.
  • Check enclosure clearance against 110.70mm x 86.10mm footprint and 75.20mm max height.
  • Resolve the RoHS conflict before release; E050TC is marked both compliant and non-compliant.