50VA max, chassis mount, dual primary, single secondary with multiple taps, 75.20mm max height
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | SolaHD |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 50VA CHAS MT |
| Key electrical range | Power - Max: 50VA; Supply and Demand Status: Shortage |
| Reported stock | 2 pcs reported — confirm on RFQ |
Can you still design E050TF in?
Can you buy it in time? Yes, but supply is the first issue to clear. E050TF is marked Active with low lifecycle risk, so there is no lifecycle reason to keep it out of a new build. The real problem is availability: listed stock is 2 and the demand flag is Shortage, which makes this less a routine transformer choice and more a line-planning decision.
The compliance picture is not settled either. One field says RoHS Compliant and another says RoHS Non-Compliant, so EU RoHS status remains unresolved from this record alone. That does not rule the part out, but it does block a clean release where the compliance file has to be firm.
50VA is the ceiling that sets the job
50VA is the listed ceiling, and that immediately frames the role: E050TF belongs in a modest mains-frequency power stage, not a heavier supply. Beyond that, the number does not carry the design by itself. It does not give output voltage, output current, regulation, or thermal rise, so it cannot size the downstream rail or the copper around it.
Mechanical fit matters almost as much here. A 110.70mm L x 86.10mm W body with 75.20mm max seated height will not disappear into leftover space late in layout. Chassis mount also pulls the enclosure and mounting scheme into the design early.
This is a box-build transformer, not a board-space afterthought
It fits box builds.
E050TF belongs in equipment that expects a laminated core and chassis mounting, with mechanical and electrical decisions tied together early rather than cleaned up at the end. The solder and quick-connect terminations point the same way: this part wants deliberate wiring and service access, not a dense PCB-only assembly where every interconnect is already fixed by copper.
The winding arrangement narrows fit further. Dual primary gives input-side configuration flexibility, and a single secondary with multiple taps can support more than one secondary voltage option from one transformer. Even so, the listing still leaves out the numbers that close the electrical choice. No primary voltage is listed, no secondary voltage is listed, no output current maximum is listed, and no isolation voltage is listed, so mains compatibility, fuse selection, downstream rectifier sizing, and safety spacing decisions are still open. That is the real limit on E050TF today, more than the Active lifecycle badge.
The missing datasheet items are the electrical ones
The constraint is missing operating detail. Primary voltage, secondary voltage at full load, output current maximum, and isolation voltage are the gaps that stop closure here.
View the Win-Source product page for E050TF.
Key Takeaways for Engineers & Buyers
- Reserve E050TF early if the build needs it; listed stock is 2 and supply status is Shortage.
- Check the enclosure stack for 110.70mm x 86.10mm footprint and 75.20mm max seated height before release.
- Pull the manufacturer compliance declaration for E050TF because RoHS Compliant and RoHS Non-Compliant both appear.