SolaHD E075E active 75VA chassis transformer

E075E SolaHD product image

75VA ceiling, 120V/240V dual primary, 24V full-load secondary, chassis-mount laminated core

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBox
Core functionPWR XFMR LAMINATED 75VA CHAS MT
Key electrical rangePower - Max: 75VA; Supply and Demand Status: Shortage; Voltage - Primary: 120V, 240V; Voltage - Secondary (Full Load): 24V
Reported stock3 pcs reported — confirm on RFQ

75VA is the real design gate

75VA is the gate. It is a ceiling, not a target, and it still leaves output current, temperature rise, and ambient headroom unanswered.

Use it for new builds, but buy it like a constrained part

This one works.

Nothing in the lifecycle picture blocks a new design-in. E075E is active, the electrical shape is familiar, and the part gives you dual 120V/240V primary windings feeding a single 24V secondary at full load in a laminated-core chassis-mount package. That suits line-powered equipment that already expects a bolted transformer, has wiring access, and can absorb a 110.70mm L x 86.10mm W body with 75.20mm maximum seated height.

The constraint is supply. Stock is 3 and the line is marked Shortage, so this is a controlled-build part, not something to drop into a broad rollout and assume will stay easy to source quarter after quarter without a real allocation plan tied to the BOM. No center tap also narrows where it fits, because designs that need split secondary rails will need extra circuitry or a different transformer.

RoHS compliance removes one routine objection. It does not fix availability.

Wrong for low-profile boards, right for chassis iron

Wrong first: low-profile board-level power stages and designs that need a center-tapped secondary. Chassis mount, solder and quick-connect terminations, and a 75.20mm maximum seated height place E075E in equipment with room for a boxed laminated transformer and the wiring space to support it.

Where it fits is conventional mains-frequency power conversion inside enclosures that already budget mechanical volume for magnetics. The dual primary winding does real work here, since both 120V and 240V are listed and one transformer can cover either mains arrangement when the wiring scheme matches the product. The 24V secondary is stated at full load, but that still does not answer regulation behavior above and below load, so the listed secondary voltage is only part of the rail story.

The missing numbers are the ones that close the review

And that is the holdback. The listing does not give output current, isolation voltage, weight, pinout, or a mechanical drawing.

For a chassis transformer, those are the details that close the decision. Output current turns the 75VA ceiling into a usable load plan, isolation voltage closes safety-spacing assumptions, and the drawing plus pinout determine whether the mounting pattern and terminations land cleanly in the enclosure.

There is also no temperature-rise or thermal derating information here. Without it, ambient headroom stays open once the transformer is boxed near other heat sources.

View the Win-Source product page for E075E.

Key Takeaways for Engineers & Buyers

  • Reserve E075E only for builds that need a 24V full-load secondary from a dual 120V/240V primary.
  • Check the chassis for 110.70mm x 86.10mm footprint and 75.20mm max seated height before release.
  • Place a buy now if E075E is on the BOM; stock is 3 and supply status is Shortage.