SolaHD E1000 active, but buy only against demand

E1000 SolaHD product image

1000VA ceiling, chassis mount, 141.20mm max height, dual primary and single secondary decide the fit.

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 1000VA CHAS
Key electrical rangePower - Max: 1000VA; Supply and Demand Status: Shortage
Reported stock1 pcs reported — confirm on RFQ

Can you design E1000 into a new build?

Can it fit the build you already have in mind? Yes—if the mechanical envelope and winding scheme already line up. No—if you still need the transformer itself to give you electrical flexibility.

E1000 is an Active chassis-mount laminated-core power transformer with a 1000VA maximum rating, dual primary windings, a single secondary winding, no center tap, and a 141.20mm maximum seated height. Those are the facts that decide fit first.

The 1000VA figure is a ceiling, not a normal operating point, so it answers only part of the selection question. It places the part in the right load class, but it does not give output voltage, output current, regulation, or thermal rise, because those values are not shown here. The winding arrangement matters just as much: dual primary gives mains-side configuration options, while the single secondary with no center tap rules out designs that need split rails or a center-tapped secondary unless you add more magnetics. Chassis mounting and solder or quick-connect terminations also push E1000 toward cabinet and panel builds rather than dense board-level power stages, where footprint and lead dress usually decide the outcome first.

The weak point is supply, not lifecycle

The weak point comes first: stock is 1 and supply status is Shortage. Lifecycle is still Active, so this is a supply problem, not an end-of-life one. Buy E1000 against committed demand. EU RoHS is compliant.

Fit is clear; the electrical picture is not

Fit is clear.

E1000 belongs in mains-frequency power conversion where a laminated core and chassis mounting are normal choices. The 141.20mm maximum height is the mechanical gate; in a tight enclosure, that number can eliminate the part before the 1000VA ceiling matters. Solder and quick-connect terminations point the same way, toward harnessed or panel wiring rather than drop-in board assembly.

What blocks electrical signoff is the missing data. There is no primary voltage, no secondary voltage at full load, no maximum output current, and no isolation voltage. That leaves E1000 in the right product class, but not ready for a specific rail plan.

The missing items are the ones that finish the review

And those gaps are not cosmetic. For E1000, the missing primary voltage, secondary voltage at full load, and maximum output current are the electrical limits that decide whether the transformer can feed the intended rails at all. The isolation-voltage field is also absent, and that affects safety spacing strategy and test planning.

Mechanical detail is thin too. Size and dimensions are not listed beyond the 141.20mm maximum height, and weight is blank. For a 1000VA chassis-mount transformer, those omissions affect enclosure layout, mounting hardware choice, and shipping assumptions more than any generic description will.

View the Win-Source product page for E1000.

Key Takeaways for Engineers & Buyers

  • Reserve E1000 only for builds that can absorb a 141.20mm max seated height.
  • Match the transformer plan to dual primary and single secondary before releasing the BOM.
  • Treat the 1000VA figure as the ceiling and lock supply early; stock is 1 and status is Shortage.