SolaHD E100TH active, but buy it like a shortage part

E100TH SolaHD product image

100VA ceiling, chassis mount, dual secondary, single primary with multiple taps, 114.30mm x 113.80mm x 98.80mm max

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 100VA CHAS MT
Key electrical rangePower - Max: 100VA; Supply and Demand Status: Shortage
Reported stock5 pcs reported — confirm on RFQ

Wrong for dense boards; right for cabinet power iron

Not for compact PCB power stages. This is a chassis-mount laminated transformer with a 114.30mm L x 113.80mm W body and 98.80mm maximum seated height, so it belongs in enclosures that already expect bolted magnetics and wiring, not in low-profile assemblies where transformer height and footprint fight everything around them.

A better fit is mains-frequency power conversion that wants a single primary with multiple taps and dual secondary windings. The no-center-tap secondary closes off designs built around a center-tapped rectifier arrangement, while the multiple primary taps only help if the missing voltage table matches your mains plan. E100TH is Active and EU RoHS compliant, so the part itself is viable for new work.

100VA is the ceiling that sets the whole conversation

100VA is the listed ceiling. That sets the frame for everything else: modest chassis power supplies, control cabinets, and serviceable industrial assemblies are in scope, but without primary voltage, secondary voltage, and output current figures, you still cannot tell whether the transformer supports the rails you need at the turns ratio your design requires.

The mechanical numbers carry nearly as much weight as the VA rating because laminated iron at this size drives enclosure layout, wiring dress, and mounting hardware choices before regulation or temperature rise even enters the discussion. At 114.30mm L x 113.80mm W with 98.80mm maximum seated height, E100TH takes real volume inside the box, and ignoring that leads to the most ordinary expensive mistake: the transformer works on the schematic and misses the chassis.

Termination style adds another practical limit. Solder and quick connect points to wired assemblies, not a casual board-edge add-on, so the design leans toward harnessed power entry and service access. The dual secondary winding count is useful structurally, but until the missing secondary voltages appear, it still does not tell you whether those windings support split rails, series connection, or isolated auxiliary outputs in your build.

Buy it for a running plan, not a casual prototype

Supply is tight.

Availability, not lifecycle, is what changes the decision here. Stock is 5 and the supply status is Shortage, which means E100TH can be the right electrical choice and still stop a build if it lands on a BOM before enough pieces are secured for the first run and spares.

That matters more than it sounds, because the part is not a generic low-profile transformer you swap late without touching mechanics, wiring, and the secondary plan. The chassis-mount laminated format, the 100VA ceiling, the single primary with multiple taps, and the dual secondary winding structure all narrow the field, so a thin supply position is a program risk, not just a purchasing annoyance.

Buy with intent. If this transformer matches the electrical plan, line coverage needs to be secured early.

The missing voltages are the real blocker

And that is the real blocker. The listing does not give primary voltage, secondary voltage at full load, output current, isolation voltage, weight, pinout, or mechanical drawing.

View the Win-Source product page for E100TH.

Key Takeaways for Engineers & Buyers

  • Reserve mechanical space for 114.30mm L x 113.80mm W and 98.80mm max seated height.
  • Treat 100VA as the loading ceiling; match the secondary plan before releasing E100TH to layout.
  • Place the buy now: stock is 5 and supply status is Shortage.