100VA ceiling, chassis mount, laminated core, 117.10mm x 86.10mm footprint, no center tap
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | SolaHD |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 100VA CHAS MT |
| Key electrical range | Power - Max: 100VA; Supply and Demand Status: Shortage |
| Reported stock | 5 pcs reported — confirm on RFQ |
100VA is the real design gate here
100VA is the ceiling that decides whether this transformer belongs in the conversation at all. It marks E100WB as a mains power transformer for a meaningful load, not a signal magnetics part, yet it still leaves out the primary voltage, secondary voltage, and output current needed to wire the rest of the supply with confidence.
Mechanically, the commitment is just as real. Chassis mount, laminated core construction, and a 117.10mm L x 86.10mm W footprint point to a box-level transformer with mounting and space consequences rather than a part that disappears onto a crowded PCB. It needs room.
Wrong for rail selection, right for box-mounted power entry
Wrong for rail selection is the cleanest way to frame it. The listing gives no primary voltage, no secondary voltage at full load, no output current ceiling, and no isolation voltage, so it cannot settle the transformer-choice questions that drive rectifier choice, capacitor voltage, and fuse strategy.
It does fit a chassis-mounted supply build that already knows it wants a laminated-core transformer around the 100VA class, with solder or quick-connect terminations instead of a board-mounted package. No center tap matters too. If the rectification scheme expects a center-tapped secondary, this one is out before layout starts.
Can you actually buy it now?
Can you actually buy it now? Not freely. E100WB is Active, but it is marked Shortage and stock is 5. If the part is already qualified, buy against immediate demand now instead of assuming replenishment will be easy.
And that shortage is not the only thing unresolved
And it is not the bigger problem. The real engineering gap is the missing data that turns a transformer description into a design decision. Primary and secondary voltages are absent, and the output current rating is missing too, so 100VA alone cannot show how the windings are meant to be used.
The listing also leaves out height, isolation voltage, and weight. Height sets enclosure clearance and can create mounting hardware conflicts. Isolation voltage determines whether the transformer meets the insulation target of the supply architecture. Weight matters because a chassis-mounted laminated part can change mounting stress and shipping behavior, especially once the enclosure, hardware, and handling loads are considered together.
That leads to a direct conclusion. E100WB works for new design-in only when those missing transformer specifics are already fixed in another approved document; otherwise, it is a sustaining-line buy rather than a fresh selection. EU RoHS is compliant, but that will not be the release blocker.
View the Win-Source product page for E100WB.
Key Takeaways for Engineers & Buyers
- Reserve board and enclosure space for 117.10mm L x 86.10mm W before releasing the mechanical layout.
- Do not assume a center-tapped secondary; E100WB is listed as No center tap.
- Place the buy now if E100WB is already approved, because stock is 5 and status is Shortage.