C&K Components E101SD1AV2BE active, but buy carefully

E101SD1AV2BE C&K Components product image

20 V AC/DC ceiling, 0.4VA load limit, SPDT On-On, right-angle through-hole, IP57, -30°C to 85°C

Quick Engineering Summary

FieldValue
ManufacturerC&K Components
CategoryToggle Switches
PackageBulk
Core functionTOGGLE
Key electrical rangeCurrent Rating (Amps): 0.4VA (AC/DC); Supply and Demand Status: Shortage; Temperature Range - Operating: -30°C ~ 85°C; Voltage Rating - AC: 20 V
Reported stock1 pcs reported — confirm on RFQ

Active part, constrained buy

Buy carefully.

Lifecycle is not the problem here. E101SD1AV2BE is listed Active with low lifecycle risk, so there is no lifecycle reason to avoid a new design, but the supply picture is much tighter than that status suggests: stock is listed as 1, the workbook also shows 1, and the demand signal says Shortage.

The electrical envelope is narrow enough that this switch belongs in low-energy manual control, not in anything expected to interrupt meaningful load. The 0.4VA (AC/DC) rating and 20 V AC and 20 V DC ratings are ceilings, and they leave open the questions that usually break a small toggle in practice, including inrush, lamp loads, motor loads, and contact life under abuse, because none of that is stated here. E101SD1AV2BE fits an existing control panel or a new low-power interface where sealing matters, but don't build a broad running line around a part showing shortage and effectively no loose stock. The RoHS story also conflicts, so compliance is still unsettled.

Will it carry the load you have in mind?

Can you stay inside 0.4VA?

That is the first real filter, because it rules out the most bad assumptions fastest. The listing gives 0.4VA (AC/DC), plus 20 V AC and 20 V DC. Those are ceilings, not operating points, and they do not say the switch is comfortable near those limits across every load type.

For fit, the consequence is straightforward: use E101SD1AV2BE where the toggle is selecting or routing a small signal or a very light control load, not where it must break inductive energy, survive heavy inrush, or stand in for a power switch. SPDT with On-On function makes it a maintained changeover device, so it suits mode select, enable paths, or low-level routing. It does not answer momentary control needs, and it does not answer higher-voltage rails just because the mechanism is panel-facing.

12.70mm sets the human interface and the board geometry

12.70mm sets the stack.

It fixes how far the standard round actuator stands proud, and together with through hole, right angle, vertical mounting, and PC pin termination, it shows a switch meant to bridge panel access and a board-mounted layout rather than float on wires.

That combination works when the PCB sits parallel to the panel and you want the switch body anchored by soldered pins, with the actuator presented at the enclosure face. The unthreaded bushing matters too: if your enclosure concept expects a threaded panel fastener, this listing does not give you one. IP57 helps around the actuator area for dust and water exposure, but it is not a blanket statement about the whole assembly once mounted in your panel cutout. The operating range of -30°C to 85°C is a boundary, not proof of outdoor or under-hood suitability.

20 V is only half the story

20 V is only the rail ceiling.

The missing half is the detail that decides whether E101SD1AV2BE survives real switching events.

What is absent matters more than another restatement of SPDT. There is no contact resistance figure, no electrical life or mechanical life, no bounce spec, and no panel cutout or drawing in this listing. For a sealed toggle, those omissions block the last step of selection because they decide signal integrity, service interval, and whether the hardware actually fits the enclosure. The compliance conflict is another gap, not a footnote: one field says RoHS Compliant and another says RoHS Non-Compliant.

View the Win-Source product page for E101SD1AV2BE.

Key Takeaways for Engineers & Buyers

  • Keep E101SD1AV2BE on signal-level or very light power paths; 0.4VA at 20 V AC/DC is the load ceiling, not a comfort margin.
  • Lock the mechanical stack early: right-angle vertical through-hole, PC pins, unthreaded bushing, 12.70mm standard round actuator.
  • Stop the release on compliance until the RoHS Compliant versus RoHS Non-Compliant conflict is cleared.