300 V, 18 AWG, 2-conductor cable rated -20 °C to 75 °C with PVC insulation and 304.8 m length
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | General Cable/Carol Brand |
| Category | Custom Parts (E - I) |
| Package | Not listed for this part |
| Core function | CABLE 2COND 18AWG GRAY |
| Key electrical range | Max Operating Temperature: 75 °C; Min Operating Temperature: -20 °C; Supply and Demand Status: Limited; Voltage: 300 V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you design E1030S.30.10 in today?
Can you actually get it? Yes, but supply is the catch.
E1030S.30.10 is Active and EU RoHS compliant, yet stock is 1 and demand status is Limited.
300 V is the ceiling that decides the circuit class
300 V sets the boundary first.
That rating is a cable ceiling, not a working target, so E1030S.30.10 belongs on runs whose insulation system stays within it. The temperature range draws the next line: -20 °C to 75 °C defines where the cable can live, but says nothing about overload headroom, bundling, or hot-spot behavior inside a crowded enclosure. The listed application notes point to control, alarm, security, and audio wiring, and the 18 AWG, 2-conductor construction fits that picture, but no ampacity or derating data appears here.
That pushes E1030S.30.10 toward fixed low-count wiring
And that narrower fit matters more than the short description suggests.
E1030S.30.10 is a multi-conductor cable with 2 conductors, copper conductors, PVC insulation, a 3.6576 mm insulation diameter, and 381 µm insulation thickness, so the practical read is a small fixed run where modest conductor count, a defined outer build, and a full 304.8 m pull length from one package all matter at once.
It does not read like a cable for high-temperature routing, and it does not yet read like one for repeated flex. The listing gives cable, grey jacket, and PVC, but it stops short of the details that usually settle installation choices: strand count is absent from the main specifications, and there is no bend data, shield data, or drawing to close out termination hardware and routing space. The details also mention solid conductor and pull string, which could change handling and installation decisions, but the page still leaves the construction picture incomplete.
Short version: E1030S.30.10 fits straightforward building or panel wiring better than anything dynamic.
The weak point is not lifecycle, it's what the listing omits
Fair point: the omissions are the problem, not lifecycle.
For E1030S.30.10, the missing pieces are concrete mechanical and installation details: the drawing, the full conductor construction, the pinout-equivalent core identification beyond grey jacket color, and any bend or flex guidance.
That still leaves one clear conclusion. You can place E1030S.30.10 in the right voltage and temperature class, but this page does not finish connector selection, routing clearance, or handling rules.
View the Win-Source product page for E1030S.30.10.
Key Takeaways for Engineers & Buyers
- Hold E1030S.30.10 to circuits that stay within the 300 V cable rating.
- Use E1030S.30.10 only where -20 °C to 75 °C matches the installed environment.
- Buy now if this exact 304.8 m cable is required; stock is 1 and supply is Limited.