150VA, chassis mount, 132.30mm x 114.30mm, 98.80mm max height, single primary and secondary with multiple taps
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | SolaHD |
| Category | Power Transformers |
| Package | Bulk |
| Core function | PWR XFMR LAMINATED 150VA CHAS MT |
| Key electrical range | Power - Max: 150VA; Supply and Demand Status: Shortage |
| Reported stock | 4 pcs reported — confirm on RFQ |
150VA is enough to justify a new design-in
150VA puts this in real mains-frequency power work, not signal duty or a light auxiliary rail. With a laminated core and chassis mounting, the mechanical envelope belongs in the design from the start rather than getting squeezed in later.
The fit still depends on electrical details that are not shown here. The listing gives single primary and single secondary windings with multiple taps, but it does not give primary voltage, secondary voltage, output current, or isolation voltage. E150JN is a valid new design-in candidate only when that missing table is already covered by the full datasheet or an approved internal part file. Lifecycle is Active and EU RoHS is compliant, so the blocker is not status. It's the missing electrical definition.
The package and height will decide the enclosure first
That carries straight into the enclosure. Chassis mount, 132.30mm L x 114.30mm W, and 98.80mm maximum seated height demand real floor area and vertical clearance, not a crowded PCB corner or a low-profile box.
Termination style matters too. Solder and quick connect point to wiring and service-access choices outside the board, and the lack of a center tap narrows the obvious use cases if the rectifier or split-rail scheme expects one. Multiple taps on both primary and secondary add flexibility, but without the actual tap voltages they do not close the design. Get the mounting drawing and leadout before committing panel space, because the footprint class is clear while the exact connection plan is not.
Shortage is the real buying constraint
Shortage sets the limit. With stock at 4, E150JN works for sustaining builds or qualification samples, not for a release that needs immediate line support.
What the listing still does not answer
150VA is decisive, but not sufficient.
The missing items are the ones that actually close the review: primary voltage, secondary voltage at each tap, maximum output current, and isolation voltage are all absent here. Any one of them can rule out E150JN even when the size and mounting fit. The mechanical picture is incomplete too. There is no pinout or terminal map, and no mounting drawing beyond overall size and maximum height. With solder and quick-connect terminations, that gap matters because wiring orientation and hardware access can stall an enclosure release just as quickly as an electrical mismatch. E150JN looks like a legitimate chassis transformer candidate, but the winding table and drawing still have to come from the datasheet.
View the Win-Source product page for E150JN.
Key Takeaways for Engineers & Buyers
- Reserve mechanical volume for 132.30mm x 114.30mm and 98.80mm max height before layout freeze.
- Treat 150VA as the loading ceiling; size the secondary load from the full electrical datasheet, not from this listing.
- Place a buy now if E150JN is already approved; stock is 4 and supply status is Shortage.