3A AC, 125 V AC, DPDT panel mount, -10°C to 70°C: enough to match an existing switch, not start a new one
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | NKK Switches |
| Category | Toggle Switches |
| Package | Bulk |
| Core function | PULSE XFMR 1CT:2. |
| Key electrical range | Current Rating (Amps): 3A (AC); Temperature Range - Operating: -10°C ~ 70°C; Voltage Rating - AC: 125 V |
| Reported stock | 29000 pcs reported — confirm on RFQ |
3A AC is the number that decides this switch
3A AC is the ceiling that matters first. It places E2023 in modest AC line switching for an existing panel assembly, while leaving DC interruption, surge handling, and inductive-load behavior unanswered because none of those limits are listed.
The other hard stop is 125 V AC. That is a ceiling, not a target rail, so it rules out higher-voltage mains hardware. With DPDT contacts and an On-Off-On function, E2023 can match a maintained three-position operator interface, but only where the load and voltage stay inside those listed AC limits.
The weak point is lifecycle, not mechanics
Discontinued is the problem, even before fit. Mechanically, the picture is clear enough for a sustaining buy: panel mount, solder lug termination, M6 x 0.75 bushing thread, 6.50mm circular cutout, and a 10.50mm standard round actuator. Those are the numbers that keep an existing front panel from turning into a metalwork change.
Electrical life is listed at 20,000 cycles. That helps frame service expectations, but it does not answer abuse tolerance or field life under a specific load profile. The RoHS story is also unresolved: one field says compliant and another says non-compliant, so treat compliance as open until that conflict is cleared.
The constraint is missing load detail
The constraint is missing load detail. No DC rating, no contact resistance, no dielectric strength, and no bounce or timing data are listed. For a maintenance build, an approved assembly may already answer those points. For a fresh circuit, it doesn't.
Buy only against a bridge plan
And that is why the stock number matters less than it first appears. There are 29000 pieces listed, in bulk, with a standard package of 1 pcs, so E2023 can support a controlled last-time buy for a running line without forcing reel or tray assumptions into stores flow.
What that quantity does not solve is lifecycle risk, because the conflict is only between bad outcomes: EOL in one field and Discontinued in two others. For new design-in, stop there. For sustaining demand, buy to a dated consumption plan, tie each order to the exact DPDT On-Off-On function and panel hardware, and avoid overbuy just because the count looks comfortable.
The remaining gaps are concrete. There is no contact resistance, no dielectric or insulation-withstand figure, no DC switching rating, and no drawing or pinout detail beyond solder lug termination. Those omissions are manageable when E2023 is replacing itself in an approved assembly, but they block a clean choice when the switch is still being selected.
View the Win-Source product page for E2023.
Key Takeaways for Engineers & Buyers
- Freeze the panel hardware around the M6 x 0.75 bushing and 6.50mm cutout before buying E2023.
- Keep load checks at or below the listed 3A AC and 125 V AC ceilings; this listing gives no DC rating.
- Resolve the RoHS conflict before release: one field says compliant, another says non-compliant.