Pulse E2023NLT active for new 10BASE-T designs

E2023NLT Pulse product image

200µH, 1:2.5 transmitter ratio, SMD, 0°C to 70°C, 0.210" max height for 10BASE-T isolation

Quick Engineering Summary

FieldValue
ManufacturerPulse
CategoryPulse Transformers
PackageNot listed for this part
Core functionXFRMR LAN ISOL 10BASET 1:2.
Key electrical rangeSupply and Demand Status: Balance
Reported stock1260 pcs reported — confirm on RFQ

The temperature ceiling is the first real limit

The first hard constraint is temperature. E2023NLT is rated for 0°C to 70°C, and that ceiling decides quickly whether it belongs in the build. It rules out outdoor, cold-start, or hot-box hardware unless the rest of the assembly stays inside that window.

Height is the other immediate limit: 0.210" (5.33mm) seated maximum. Useful, but narrow. It settles z-height and little else, because this listing does not give coplanarity, pad geometry, or solder-joint behavior. For fit, though, it says enough to place E2023NLT as a compact SMD LAN transformer for board-level Ethernet isolation rather than a general-purpose line transformer.

Can you keep E2023NLT on a running line?

Can you actually buy and build with it? Yes, if reel-only supply fits the way your line runs.

E2023NLT is listed as Active, with supply and demand at Balance and inventory at 1260. That supports a planned reel-based build, but it is not the kind of stock position you treat as a cushion for every future pull if the assembly turns into a high-run item.

Packaging is the practical issue. The listing shows Reel - TR only, so the manufacturing path is straightforward for tape-and-reel SMT intake and less flexible if you need alternate pack styles for service stock, lab issue, or hand-load spares. The handling note matters too: dry storage cabinet and humidity protection package points to disciplined moisture control once reels are opened, especially if E2023NLT sits between receiving and placement longer than expected.

Compliance is simple. EU RoHS is listed, and there is no lifecycle conflict in the page data.

This is a 10BASE-T magnetics part, not a generic transformer

Keep it narrow.

The description calls out LAN isolation for 10BASE-T, and the transformer type is isolation and data interface, encapsulated. That places E2023NLT in Ethernet front-end magnetics, where the turns information and inductance support a network interface role rather than power transfer.

The ratio detail is what changes a schematic decision: 1CT:2.5CT transmitter and 1CT:1CT receiver. E2023NLT is not a single-ratio pulse transformer, and a mismatch here will show up fast between the PHY-side expectation and the magnetics network. The 200µH inductance supports the intended use, but it does not settle insertion loss, return loss, or isolation performance.

200µH is useful, but the missing curves still decide the review

200µH is the anchor figure.

It tells you E2023NLT is specified beyond a bare mechanical shell, and you can pair that with the listed 0.495" x 0.280" body size and 0.210" height to judge footprint and enclosure fit. What it does not do is answer the electrical questions that usually decide Ethernet magnetics signoff, because this listing does not include isolation voltage, insertion loss, return loss, or common-mode rejection.

The missing items are concrete: no pinout, no drawing, no ET value, and no full electrical table here. Those details drive routing, center-tap handling, and whether E2023NLT matches the exact PHY and connector topology you need to close.

View the Win-Source product page for E2023NLT.

Key Takeaways for Engineers & Buyers

  • Keep E2023NLT on 10BASE-T magnetics only; the description names 10BASE-T and not faster Ethernet.
  • Check enclosure height against the 0.210" (5.33mm) seated maximum before freezing placement.
  • Buy on reel; E2023NLT is listed only in Reel - TR packaging and stock shows 1260.