C&K Components E213J60V8QE2 active, but buy carefully

E213J60V8QE2 C&K Components product image

7.5A (AC/DC), 125 V AC, 28 V DC, through-hole PC pins, -30°C to 85°C, SP3T On-On-Mom

Quick Engineering Summary

FieldValue
ManufacturerC&K Components
CategoryRocker Switches
PackageBulk
Core functionSWITCH ROCKER SP3T 7.
Key electrical rangeCurrent Rating (Amps): 7.5A (AC/DC); Supply and Demand Status: Shortage; Temperature Range - Operating: -30°C ~ 85°C; Voltage Rating - AC: 125 V
Reported stock1 pcs reported — confirm on RFQ

7.5A sets the contact ceiling, not the application

7.5A (AC/DC) is the first gate. It sets the contact ceiling for E213J60V8QE2, not blanket approval for every 7.5A load, and it leaves inrush, motor duty, and lamp loads unresolved because those figures are not listed.

The voltage limits narrow the fit further: 125 V AC and 28 V DC. If your design goes above 28 V DC, this switch is out before mechanics even enter the discussion. That's the real screen.

SP3T is real here, but only if you design in the jumper

125 V AC puts this rocker in range for mains-adjacent panel control, but the listing also spells out the catch that matters more than the headline function. E213J60V8QE2 is identified as SP3T with an On-On-Mom function, and the feature note says a jumper is required to achieve triple throw, so the schematic, assembly instructions, and failure analysis all need to account for that added element rather than treating SP3T as inherent to the base switch.

Mechanically, the direction is clear. Through Hole mounting and PC Pin termination point to a board-mounted part, not a flying-lead harness switch. The paddle actuator is unmarked, and the cap is black with no legend, so any position labeling has to happen elsewhere on the panel if the interface needs to be self-explanatory in use.

The environmental boundary is also plain: -30°C to 85°C. That range covers ordinary industrial and commercial ambient conditions, but it also sets a hard ceiling for hotter enclosures unless the rest of the thermal stack stays inside it. What still is not shown matters: contact resistance, dielectric strength, panel cutout, and sealing. Those details decide whether the switch merely fits the BOM or actually fits the product.

The weak point is supply, not lifecycle

Shortage is the problem; Active status is not. E213J60V8QE2 is not shown as end-of-life, but one stock field shows 1 while another quantity field shows 81, and that mismatch is enough to disrupt release planning.

For a new build, buy against committed demand instead of assuming spot stock will support a running line. For sustaining production, reserve the required quantity before you freeze the build around E213J60V8QE2. EU RoHS compliance and cULus approval help on the compliance side, but they do nothing for a short line.

What is still missing before release

What does a buyer need answered first? Panel cutout, sealing, and contact resistance. The listing also does not show dielectric strength, insulation resistance, or a drawing for the jumper implementation that creates the SP3T behavior.

View the Win-Source product page for E213J60V8QE2.

Key Takeaways for Engineers & Buyers

  • Treat 7.5A (AC/DC) as the contact ceiling; don't use it to infer lamp or motor inrush behavior.
  • Wire the jumper into the schematic now if you need the SP3T function; it is required to achieve triple throw.
  • Cover -30°C to 85°C in the environmental matrix before release, especially if the panel sees outdoor or cold-start service.