7M extension cable, bulk pack, discontinued status; fit is simple, continuity is not.
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Sensors, Transducers Accessories |
| Package | Bulk |
| Core function | ACCESSORY EXTENSION CABLE 7M |
| Key electrical range | Not listed for this part |
| Reported stock | 1 pcs reported — confirm on RFQ |
The bad news comes first: don't start a new build on it
The weak point comes first. E22-XC7R is marked Discontinued, while another lifecycle field says EOL; that conflict does not reopen the part for new design-in, it only shows that the retirement wording is messy.
The stronger point is narrower. If you are keeping an existing machine or fielded sensor assembly alive and the exact cable matters, E22-XC7R is at least clearly identified as an accessory extension cable at 7M. RoHS is listed as EU RoHS compliant, removing one routine compliance objection, but the main decision does not change: this part is off the table for fresh programs.
Fit is narrow
Fit is narrow.
E22-XC7R belongs in a small box. The category is Sensors, Transducers Accessories and the description is ACCESSORY EXTENSION CABLE 7M, so the clean use case is extending an existing sensor connection where that exact cable role and length are already known to be correct. It does not answer connector form, conductor details, shielding, or current handling, so it cannot settle a new cable-spec decision on its own.
Bulk packaging matters too, especially for a cable item headed into service stock or bench repair, but it adds nothing for kitting discipline or assembly presentation.
7M is the one number that actually decides fit
7M is the deciding number.
It is a fit limit, not a performance guarantee. The listing tells you E22-XC7R is meant for a cable run of that stated length; it does not tell you voltage drop, noise pickup, bend radius, or what sensor timing margin survives after the extension is added.
That gap matters because extension cables can fail quietly, with a machine that powers up, then shows intermittent sensing or false trips after the added run changes the electrical behavior. Bulk is only a supply format, not a mechanical or environmental rating.
One piece left is the real buying constraint
1 piece is listed.
That turns this into a service decision, not a sourcing strategy. With E22-XC7R already discontinued, a stock quantity of 1 means you buy only against a named unit in the field or a specific sustaining build that cannot ship without this exact accessory.
Do not spread that single piece across forecast demand in your head. Reserve it for the machine that is down or for the customer return that needs the original cable assembly restored, then remove E22-XC7R from any open new-build BOM before it becomes a line stop.
The lifecycle conflict between EOL and Discontinued does not soften the conclusion, because both labels point to the same operating reality: use remaining stock tactically, not as evidence of continuity, and move the cable requirement onto a supported assembly path as soon as the immediate service need is covered.
What the listing still doesn't tell you
And that leaves the other blocker: no connector detail, no pinout, no drawing, and no environmental rating are given here. Those are the missing items that would close a real cable review.
View the Win-Source product page for E22-XC7R.
Key Takeaways for Engineers & Buyers
- Lock E22-XC7R to existing builds only; discontinued status rules out new programs.
- Match the cable run to the listed 7M length before touching the BOM.
- If you need E22-XC7R now, act on the single unit shown and clear the service demand first.