MORNSUN Science& Technology Ltd. E2412S-2WR3 for sustaining only

E2412S-2WR3 MORNSUN Science& Technology Ltd. product image

21.6V to 26.4V input, dual ±12V outputs at 83mA max, 3 kV isolation, through-hole 7-SIP module

Quick Engineering Summary

FieldValue
ManufacturerMORNSUN Science& Technology Ltd.
CategoryPower Supplies Board Mount DCDC Converters
PackageTube
Core functionDC DC CONVERTER +/-12V 1W
Key electrical rangeCurrent - Output (Max): 83mA, 83mA; Number of Outputs: 2; Operating Temperature: -40°C ~ 105°C (With Derating); Power (Watts): 1.99 W
Reported stock288 pcs reported — confirm on RFQ

Lifecycle conflict makes this a sustaining-line part

The constraint is lifecycle, not output power. E2412S-2WR3 shows Active in one field and Not For New Designs in another, with the same message repeated in the lifecycle signals, so the safe call is sustaining designs only.

That still leaves it usable where the board is already released and the converter is qualified in place. EU RoHS is compliant, so there is no compliance conflict on top of the lifecycle conflict. For a fresh design, E2412S-2WR3 creates a migration problem on day one, and that is a bad trade for a board-mount power module.

The rail window and output ceilings decide the fit

Don’t design this in new.

The electrical fit is narrow in ways that matter. The input range is 21.6V to 26.4V, so E2412S-2WR3 belongs on a nominal 24V rail that is already controlled inside that window; it does not answer the question for a wider industrial bus, and it leaves no room to gloss over brownout or overvoltage behavior.

The outputs are fixed at 12V and -12V, with 83mA max on each output. That is a ceiling on each rail, not a working point, and it places the module in low-power analog bias rails, interface isolation, or small signal chains that genuinely need split supplies. It does not fit where startup surges, asymmetric loading, or downstream regulators need more current headroom than 83mA allows.

Then there is the thermal and power budget. The listing gives 1.99 W, 83% efficiency, and an operating range of -40°C to 105°C with derating. That combination makes ambient headroom conditional across the temperature span, and the missing derating curve is what decides whether the enclosure still works at the hot end. In practice, E2412S-2WR3 fits controlled 24V systems with light dual-rail loads, not general-purpose power trees.

3 kV isolation is the real reason to keep it

3 kV is the number that keeps this module on some existing boards. For E2412S-2WR3, the isolation rating is the differentiator, because a dual ±12V output at 83mA max is easy to summarize but harder to keep when the design also needs galvanic separation in a compact through-hole SIP body.

The approvals and 62368-1 reference only place the part in an ITE path; they do not settle creepage, clearance, or system-level insulation questions for your board. The 7-SIP module, 5 leads package, and 19.7mm x 7.1mm x 10.2mm body make it a straightforward fit for older through-hole layouts, but they also keep E2412S-2WR3 out of dense surface-mount power sections where height and manual insertion are already under pressure.

What the listing still doesn’t answer

The weak point is documentation depth. You still need the derating curve, pinout, and mechanical drawing to close board and ambient decisions on E2412S-2WR3.

The listing also omits ripple or noise detail and any transient behavior, so it cannot tell you how clean those ±12V rails are under real load.

View the Win-Source product page for E2412S-2WR3.

Key Takeaways for Engineers & Buyers

  • Hold the input rail inside 21.6V to 26.4V; E2412S-2WR3 does not close any wider bus tolerance question.
  • Treat 83mA on each output as the ceiling for the ±12V rails, not a target load for every ambient condition.
  • Reserve the 7-SIP through-hole footprint and 19.7mm x 7.1mm x 10.2mm body before locking the board.