SolaHD E250E active transformer, buy with shortage caution

E250E SolaHD product image

250VA, 120V/240V primary, 24V full-load secondary, chassis mount, 132.30mm x 114.30mm x 98.80mm max

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBox
Core functionPWR XFMR LAMINATED 250VA CHAS MT
Key electrical rangePower - Max: 250VA; Supply and Demand Status: Shortage; Voltage - Primary: 120V, 240V; Voltage - Secondary (Full Load): 24V
Reported stock2 pcs reported — confirm on RFQ

250VA is the real design-in gate

250VA is the ceiling that decides whether this transformer belongs in the build. It sets the first pass/fail check, but it does not answer thermal rise, inrush behavior, or enclosure headroom.

Can you actually buy into E250E today?

Can you get it now? Barely.

E250E is Active, but stock is 2 and the supply status is Shortage, so this is not a part to leave floating on a new BOM while the schedule sorts itself out.

That does not block new design-in. It does mean the 24V secondary and 250VA ceiling need to be the right fit before you commit, then material should be secured early instead of assuming the next pull will be there. EU RoHS is compliant and does not add friction to the buy.

This is a chassis transformer, not a board-space problem

It needs real space.

The package description calls out chassis mount, laminated core, with solder and quick-connect terminations. That places it in cabinet, panel, and equipment builds where mounting and field wiring matter more than PCB density.

A 120V/240V dual primary gives mains flexibility at the transformer, while the single 24V secondary keeps the output side simple when the load wants one rail rather than a center-tapped arrangement. No center tap makes it the wrong choice when the downstream supply expects a split secondary straight from the transformer.

24V output is clear; the missing details are not

98.80mm is tall enough to settle the mechanical question early.

With a maximum seated height of 98.80mm, plus 132.30mm length and 114.30mm width, this transformer will not disappear into a cramped enclosure, and that matters before anyone gets too comfortable with the nominal 24V full-load secondary.

The listing gives you the basics that frame the fit: chassis mount construction, a laminated core, solder and quick-connect terminations, a dual primary for 120V or 240V input, and a single 24V secondary. That is enough to identify the kind of build it belongs in, but not enough to close the integration work in a product that has real thermal, wiring, and layout constraints.

Several concrete details are still missing. You have 24V at full load, but no output current figure is listed. You have 250VA, but no temperature rise, no regulation, and no isolation voltage. On the mechanical side, there is no mounting drawing, no pinout or terminal map, and no weight. Those are the details that decide enclosure heat, secondary sag under load, insulation margin, and whether the panel layout finishes cleanly or stalls late.

View the Win-Source product page for E250E.

Key Takeaways for Engineers & Buyers

  • Reserve E250E early if this build needs it; stock is 2 and status is Shortage.
  • Check the chassis for 132.30mm x 114.30mm footprint and 98.80mm max seated height before release.
  • Match the primary wiring to 120V or 240V and keep the load inside the 250VA ceiling.