SolaHD E250TH active chassis transformer, buy carefully

E250TH SolaHD product image

250VA, chassis mount, laminated core, dual secondary, 133.40mm x 128.80mm x 115.10mm max

Quick Engineering Summary

FieldValue
ManufacturerSolaHD
CategoryPower Transformers
PackageBulk
Core functionPWR XFMR LAMINATED 250VA CHAS MT
Key electrical rangePower - Max: 250VA; Supply and Demand Status: Shortage
Reported stock4 pcs reported — confirm on RFQ

Can you start a new build on E250TH?

Can you actually buy enough of it? That's the first question here.

E250TH is Active, so lifecycle does not block a new design, and EU RoHS compliance is clear enough that compliance is not the issue. The issue is supply: stock is 4 and the supply status is Shortage. That does not push E250TH into sustaining-only use, but it does make buy planning part of the design decision if your schedule cannot absorb a thin supply line.

The weak point is availability; the stronger case is fit

The weak point comes first: with only 4 in stock and a Shortage flag, E250TH is a poor choice for any near-term build that needs volume flexibility, field spares, or a second production pass after the first lot is gone. Bulk packaging does nothing to change that. This is a line-planning constraint.

The stronger case is fit. The part definition is specific enough to sort applications quickly: E250TH is a laminated-core power transformer rated 250VA, chassis mount, with a single primary winding using multiple taps and dual secondary windings. That points it toward equipment that expects a bolted transformer body, has panel or chassis space available, and uses discrete wiring through solder or quick-connect terminations instead of a board footprint.

That same definition also rules things out early. Chassis mount and harnessed terminations are a mismatch for layouts built around direct PCB integration, and dual secondaries without a center tap will not suit a rectifier or split-rail scheme that starts from a center-tapped secondary. In other words, the fit case is real, but only when the mechanical format and transformer topology already line up with the design.

View the Win-Source product page for E250TH.

250VA is the headline, but the envelope decides the chassis

250VA is the decisive figure. It sets the supply class this transformer can support, but as a listed maximum power figure it is a ceiling, not a normal operating point.

For mechanical fit, the harder limits are 133.40mm L x 128.80mm W and 115.10mm seated height max. Those numbers decide enclosure clearance and mounting location, and they can take space away from nearby assemblies in ways that matter long before wiring starts. It is not small.

The construction details support the same reading. Chassis mount means the mechanical structure has to carry the part and its vibration path, while solder and quick-connect terminations point to harnessed power wiring rather than direct PCB integration.

Wrong for voltage-sensitive work until the missing numbers show up

Wrong for voltage-sensitive work first: E250TH is not ready for any design where output voltage, regulation, or isolation margin is the gating decision, because those values are absent here.

The missing items are concrete and important: primary voltage, secondary voltage at full load, maximum output current, and isolation voltage are all blank. For a transformer, those are core selection inputs, not side details. They determine mains compatibility, downstream rectifier choice, fuse selection, and whether the dual secondary can be used the way you intend. The listing also does not give weight or a drawing, so mounting stress and keep-out planning still depend on the datasheet.

View the Win-Source product page for E250TH.

Key Takeaways for Engineers & Buyers

  • Reserve E250TH early if the build needs more than 4 pieces; supply status is Shortage.
  • Check the enclosure against 133.40mm x 128.80mm and 115.10mm max before releasing the chassis.
  • Confirm the required primary tap and both secondary voltages from the datasheet before locking the wiring.