Omron E2A-M08KN04-M1-B2 discontinued, sustaining only

E2A-M08KN04-M1-B2 Omron product image

10V to 32V supply, 4mm inductive range, M8 threaded body, -40°C to 85°C, PNP-NC 3-wire output

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 4MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

Can you still buy E2A-M08KN04-M1-B2 for a live build?

Can I still put this on a live build? Only if the build is already committed and there is no time left to requalify. E2A-M08KN04-M1-B2 is marked Discontinued, the lifecycle notes also carry an EOL signal, and stock is 0. That shuts the door on new design-in and turns any sustaining buy into a schedule risk rather than a sourcing choice.

The fit was never broad enough to make a casual replacement safe. This is an inductive, unshielded, 3-wire PNP-NC sensor with a 0.157" (4mm) sensing distance, a 10V ~ 32V supply range, and a threaded M8 cylindrical body, so any machine built around a different output polarity, a different default state, or a flush-mount body is already outside the lane before lifecycle status even comes up.

Compliance adds one more snag. EU RoHS status is conflicted here, with one field calling it RoHS Compliant and the specifications listing it as RoHS Non-Compliant, so sign-off needs the manufacturer declaration in hand.

The package and stock position are the real stop signs

0 on hand is the real stop sign. Bulk packaging is workable for line-side kitting; zero stock is not.

10V ~ 32V is a supply window, not a wiring pardon

10V ~ 32V is the first hard limit. It tells you where the controller rail can sit, but says nothing about output loading, voltage drop, or transient tolerance. With PNP-NC, 3-Wire, the application narrows quickly: E2A-M08KN04-M1-B2 belongs on DC sensor inputs already set up for sourcing, normally closed behavior. Put it on the wrong input style and you get false states or a dead channel.

0.157" (4mm) is the sensing distance ceiling in the listing. With an unshielded body, that also means the mounting geometry needs room around the face. The M8 threaded cylinder helps in tight fixtures, but it does not rescue a bracket laid out for a longer range or a flush installation.

Then there is 1kHz response frequency. Fast enough for many machine positions, but still a ceiling that has to cover target speed and spacing.

What the listing still doesn’t answer

And that leaves the release-critical gaps. The connector is named, but the mating format and pinout are absent, so harness compatibility is still open. The listing also omits load current, leakage, and voltage drop, the numbers that decide PLC input margin and whether an indicator or relay input will behave.

Mechanical detail is thin too. You get Cylinder, Threaded - M8 and nickel-plated brass, but no drawing, no thread length, and no body dimensions beyond M8. For an unshielded 4mm sensor, the mounting clearances matter.

View the Win-Source product page for E2A-M08KN04-M1-B2.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases on the Discontinued status.
  • Match the control input to PNP-NC, 3-wire before touching the harness.
  • Check the mechanical stack for the 4mm sensing distance and unshielded body.