Omron E2A-M12KS02-WP-B1 2M discontinued, sustaining only

E2A-M12KS02-WP-B1 2M Omron product image

10V to 32V supply, 2mm shielded M12 inductive sensor, -40°C to 85°C, cable lead termination

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUC 2MM CYL 2M CBL
Key electrical rangeOperating Temperature: -40°C ~ 85°C; Output Type: PNP-NO, 3-Wire; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

2mm sensing range makes the fit very narrow

2mm sets the fit. That 0.079" (2mm) sensing distance is the hard constraint for bracket stack-up, target travel, and contamination tolerance, so this sensor belongs in close, repeatable metal detection rather than any layout that needs generous stand-off.

The rest of the mechanical picture points the same way. It is an inductive, shielded sensor in a threaded M12 cylinder with cable leads, suited to compact industrial fixtures where flush-style mounting and a fixed cable are acceptable. It does not suit layouts that need connector serviceability, long sensing reach, or much mechanical adjustment after installation.

Can you still buy it for a running line?

Can you still get it for production support? No, not through a normal replenishment path. The part is marked Discontinued, the lifecycle signals also include EOL, and listed stock is 0.

That settles the new-design question: do not design it in. For existing production, freeze demand, search approved residual stock, and start the migration work in parallel instead of waiting for the next shortage to stop the line. RoHS status is conflicted too, with one field saying compliant and another saying non-compliant, so do not assume a clean compliance carryover on old assemblies.

The electrical limits are broad, but they don’t rescue lifecycle

The weak point comes first: it is discontinued. The stronger news is that the listed limits still line up with common industrial use, which explains why sustaining teams may want Omron E2A-M12KS02-WP-B1 2M even now.

The 10V to 32V supply range is a window, not proof that every control input and cable run around it will behave the same way. It places the sensor on common low-voltage industrial rails, but it does not answer output loading, voltage drop at the load, or transient behavior. The -40°C to 85°C operating temperature range is broad enough for outdoor equipment and washdown-adjacent machinery, yet the listing still leaves out response frequency, switching behavior, and a wiring diagram, so the environmental and control review remains open.

Ingress protection is the other rating pair that matters: IP67 and IP69K. Combined with the nickel-plated brass body, those ratings point to real factory-floor duty rather than panel-interior use. But the listing says nothing about how the 2m cable is dressed, sealed at the entry, or terminated in your harness, and that gap matters because a bad cable installation can come back as a sensor failure when the root cause sits in the assembly around it.

The missing details are the ones that close the review

10V to 32V is not enough. The listing leaves out response frequency, and that missing item decides whether the sensor can track the event rate in your mechanism or simply miss targets.

It also omits a pinout or wiring diagram, output current detail, and any dimensional drawing beyond threaded M12 cylinder. Those details decide PLC input compatibility, harness rework, and whether the sensor body and sensing face actually clear the bracket you already have.

View the Win-Source product page for E2A-M12KS02-WP-B1 2M.

Key Takeaways for Engineers & Buyers

  • Block E2A-M12KS02-WP-B1 2M on new BOMs; lifecycle is Discontinued and stock is 0.
  • Check the control input against the 10V to 32V supply window before touching the harness.
  • Confirm the target and bracket can live with the 2mm sensing distance in a shielded M12 body.