10V to 32V supply, 4mm shielded inductive range, M12 threaded body, -40°C to 70°C limits the fit
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 4MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Can you still buy this for a new build?
No.
For a new machine release, this is a walk-away part. Lifecycle Status is Discontinued, Product Status is Discontinued, and a separate lifecycle flag says EOL. The labels conflict, but none point to a healthy supply path. The practical problem is even simpler: stock is 0, so availability fails before any electrical review begins.
For existing production, treat E2A-M12KS04-WP-C2 2M as sustaining only and secure any remaining stock while you start a migration path. RoHS is listed as EU RoHS compliant, but that does not change the supply risk.
4mm decides the mechanics first
4mm sets the mechanical ceiling first.
In a shielded M12 inductive body, that closes the basic mounting and target-spacing question, but not side approach, target material sensitivity, or installation tolerance.
Then the electrical fit gets narrow fast
And it gets narrower once you look at the interface. The output is NPN-NC, 3-Wire, so the control side already has to expect a normally closed NPN sensor; if the input card or field wiring was built around another logic convention, this is not a casual substitution.
The 10V ~ 32V supply range is a window with 32V as the ceiling, and controllers on that rail still have to suit the output stage. Add the 1kHz response frequency and the part reads like a standard industrial position sensor, not a catch-all pickup.
The missing details are the ones that close the review
The weak point is documentation depth.
You have enough to reject or retain E2A-M12KS04-WP-C2 2M on lifecycle and basic fit, but not enough to close a release check. There is no pinout detail beyond NPN-NC, 3-Wire, so harness assignment remains open. There is no drawing beyond Cylinder, Threaded - M12, leaving thread length and body dimensions unresolved for bracket reuse. There is no load current figure, so input compatibility and output loading stay open. There is also no switching diagram or timing detail beyond 1kHz, which leaves debounce behavior and controller edge expectations unsettled.
The package and environmental ratings still tell you something useful. Cable leads and a nickel-plated brass body fit fixed machine mounting better than quick field replacement schemes built around detachable connectors, and IP67, IP69K, and -40°C ~ 70°C make it credible for wet washdown areas and cold starts. Those are limits, though, not proof against every chemical or mechanical abuse case.
So the decision is straightforward: if E2A-M12KS04-WP-C2 2M is already qualified in an existing machine, manage it as a support problem and lock down field demand; if it is not, stop here.
View the Win-Source product page for E2A-M12KS04-WP-C2 2M.
Key Takeaways for Engineers & Buyers
- Block new BOM releases for E2A-M12KS04-WP-C2 2M; lifecycle is Discontinued and stock is 0.
- Check the control input against NPN-NC, 3-Wire before touching the harness or PLC card.
- Use the 4mm sensing distance and 1kHz response as the first screen for machine timing and target spacing.