10V to 32V supply, 8mm sensing, M12 threaded body, -40°C to 70°C, PNP-NC 3-wire
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Box |
| Core function | SENSOR PROX INDUCTIVE 8MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 1 pcs reported — confirm on RFQ |
The real constraint is lifecycle, not sensing distance
The constraint is lifecycle. The listing shows Discontinued in lifecycle status and product status, while the lifecycle signal also carries EOL; that conflict does not reopen the part for new design-in, it supports the conservative read.
Stock is 1. That is enough for a repair or a line-down spare, not a fresh release. EU RoHS is listed, so compliance is not the blocker. Availability is.
Fit is narrow and specific
This is narrow.
It belongs in industrial proximity sensing where an inductive, unshielded head with 0.315" (8mm) sensing distance and a PNP-NC, 3-wire output already matches the control scheme. The Cylinder, Threaded - M12 body and cable leads point to machine wiring and fixed mounting, not board-level design.
IP67 and IP69K, along with a nickel-plated brass body, support washdown and dirty environments, but they do not settle the electrical interface for a controller expecting NPN or normally open behavior. Get that wrong and the input logic fails before ingress protection matters.
The listed limits close only a few decisions
10V ~ 32V is the supply ceiling and floor listed for this sensor, so it closes rail compatibility without answering noise margin, current draw, or output loading because those numbers are not here.
The -40°C ~ 70°C operating temperature range sets the ambient envelope only at the sensor level; it does not cover cable flex life, switching drift, or mounting heat rise. The 800Hz response frequency matters too, because it sets expectations for ordinary machine detection rates rather than faster events. And the 0.315" (8mm) sensing distance is a fit number, not a promise about every target condition, especially with an unshielded construction.
What the listing still does not answer
Weak point first: the electrical detail is thin.
Output current, residual voltage, current consumption, and a connection diagram are still missing.
View the Win-Source product page for E2A-M12LN08-WP-B2 5M.
Key Takeaways for Engineers & Buyers
- Lock the control input to PNP-NC, 3-wire before touching the BOM.
- Check mechanical fit around the unshielded 8mm sensing face in the M12 threaded body.
- Reserve the single listed unit only for an existing E2A-M12LN08-WP-B2 5M line stop.