Omron E2A-M18KN16-WP-C2 2M discontinued sensor

E2A-M18KN16-WP-C2 2M Omron product image

10V ~ 32V supply, 16mm inductive range, M18 threaded body, -40°C ~ 70°C, IP67/IP69K

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 16MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 32V
Reported stock1 pcs reported — confirm on RFQ

Do not design this in

Don't. E2A-M18KN16-WP-C2 2M is discontinued, and the lifecycle record only gets worse on a close read: one field says EOL and two say Discontinued, leaving no favorable interpretation for new work.

For an existing production line, the issue is immediate. Stock is listed at 1, so E2A-M18KN16-WP-C2 2M is a bridge-buy part at best. EU RoHS is compliant, but that does not change the supply picture.

Wrong for fresh platforms, usable only in matching installs

Wrong for any platform you expect to release again. Usable only where the machine already expects an unshielded inductive sensor with NPN-NC, 3-Wire output, cable leads, and an M18 threaded cylinder.

16mm decides the mechanical fit before anything else

16mm is the first filter. The listed sensing distance of 0.630" (16mm) sets where E2A-M18KN16-WP-C2 2M can sit in a machine and still see the target, but it says nothing about margin against target material, mounting metal, or approach geometry because the listing does not include those details.

The 10V ~ 32V supply range fits common industrial rails, but that answers only the rail question. It does not answer output loading, leakage, or voltage-drop behavior at the controller input. NPN-NC, 3-Wire is a wiring decision, not a preference; get it wrong and the input logic inverts or never sees the state you intended.

The real constraint is supply continuity, not ingress or temperature

Supply continuity is the constraint. The environmental numbers are the easy part: IP67, IP69K, a nickel-plated brass body, and an operating temperature range of -40°C ~ 70°C make E2A-M18KN16-WP-C2 2M plausible in washdown-prone or dirty industrial positions where a threaded metal barrel sensor is already expected, and the LED indicator helps with local troubleshooting after installation.

None of that offsets the actual problem. Discontinued status plus stock quantity 1 means the limiting factor is not ingress protection or temperature headroom but whether you can keep a build or service line running at all, especially once a single failure can consume the last available unit and turn a routine replacement into downtime.

The 400Hz response frequency is a ceiling on event rate, not a promise that every target transition in a noisy installation will be clean at that speed. It separates slow-to-moderate machine sensing from genuinely fast counting tasks, and that is where this part stops being a safe assumption.

If you still have a fielded assembly built around E2A-M18KN16-WP-C2 2M, reserve any remaining pieces for the highest-cost downtime points first, then move that assembly onto an approved migration path before service demand burns through the last unit.

Several review-closing details are still absent

3-wire is listed, but the pinout or cable conductor assignment is not. Without that, E2A-M18KN16-WP-C2 2M cannot be wired from this page alone.

The listing also omits a mechanical drawing, target specification details behind the 16mm claim, and any load or output-current limit for the NPN-NC stage.

View the Win-Source product page for E2A-M18KN16-WP-C2 2M.

Key Takeaways for Engineers & Buyers

  • Block E2A-M18KN16-WP-C2 2M from new BOM releases; lifecycle is Discontinued.
  • Check the control input against NPN-NC, 3-Wire before touching the panel wiring.
  • Use E2A-M18KN16-WP-C2 2M only where 16mm sensing and 400Hz response already match the machine.