10V to 32V supply, 8mm shielded M18 inductive sensor, -40°C to 70°C, 500Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 8MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 0 pcs reported — confirm on RFQ |
8mm decides whether this sensor belongs at all
8mm is the first gate. It puts E2A-M18KS08-WP-B3 in short-range metal detection around a fixed target, not in layouts that need extra stand-off or loose mechanical tolerance.
The real constraint is lifecycle, not sensing performance
Availability is the constraint. E2A-M18KS08-WP-B3 is marked Discontinued, the lifecycle notes also carry an EOL signal, and listed stock is 0, so it does not belong in a new machine even though the electrical envelope is ordinary for an industrial inductive sensor.
The 10V to 32V supply range settles nominal rail compatibility, but not startup behavior, wiring polarity, or output loading because those details are not here. The -40°C to 70°C operating temperature gives useful ambient coverage for factory equipment, yet it does not settle enclosure heat rise or cable-temperature limits. Keep the EU RoHS question open as well: one field says compliant and another says non-compliant.
Sustaining only.
Use it to keep an existing line running. E2A-M18KS08-WP-B3 fits where the machine already expects a shielded M18 inductive body, cable leads, and a PNP-NC/NO 3-wire output.
IP67 and IP69K ingress ratings, a nickel-plated brass body, and an LED indicator support installed industrial service, especially where washdown or contamination resistance matters more than miniaturization. The 500Hz response frequency matters in moving equipment, but it is only one timing number; it does not answer switching latency, target-size dependence, or noise behavior.
Weak listing, decent mechanical picture
Thin documentation is the problem, even if the mechanical picture is decent. The construction story is clear enough: Cylinder, Threaded - M18, shielded, cable leads, bulk pack, nickel-plated brass body.
That supports a broad fit check, but not release into a controlled drawing set. The missing items are concrete: no pinout or wire-color assignment for the PNP-NC/NO, 3-Wire output, no dimensional drawing beyond M18 and cylindrical form, no load-current figure for the output stage, and no switching-time detail beyond 500Hz response frequency. Those gaps decide PLC input compatibility, panel documentation, and whether a field replacement is plug-correct instead of merely thread-correct.
View the Win-Source product page for E2A-M18KS08-WP-B3.
Key Takeaways for Engineers & Buyers
- Block new BOM releases for E2A-M18KS08-WP-B3; lifecycle is Discontinued and stock is 0.
- Check the control input against the 10V to 32V supply window before touching the harness.
- Confirm the machine can live with 8mm sensing distance and 500Hz response before reusing the footprint.