10V to 32V supply, 8mm shielded M18 inductive sensor, -40°C to 70°C, NPN-NC 3-wire
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 8MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Still usable only if the line already ships
And that settles the main question: keep it out of new designs. The lifecycle picture is bad in every direction that matters, with Discontinued in the lifecycle status and product status, plus an EOL signal elsewhere. For an existing production build, this is a sustaining-only part, not a fresh design choice.
The supply and mechanical envelope are ordinary enough for factory sensing work, but lifecycle beats convenience here. EU RoHS is compliant, which removes one paperwork problem, not the supply problem. Stock is 0. If this sensor is already qualified in a machine, treat remaining demand as a bridge and start migration now.
32V is a rail ceiling, not a control-system answer
32V is the listed top of the supply range, with 10V at the low end, and that answers only one question: whether it can sit on the DC sensor rail you already have. It does not tell you output load behavior, voltage drop, or startup behavior, because those numbers are not here.
The 0.315" (8mm) sensing distance is the other key figure. In a shielded M18 body, it points to close-in metal target detection, where bracket geometry is controlled and the trip point stays local. Get that wrong and the field symptom is simple: missed detection, not a mysterious controller fault.
Then there is 500Hz response frequency. That is fast enough to matter in moving equipment, but it is still only a listed ceiling on switching speed, and without more timing detail this is not the part to choose for edge-case timing margins.
Wrong for open-ended retrofits, right for sealed machine sensing
Wrong first: this is a poor fit for retrofit jobs where the output logic is still undecided or where the installer wants connectorized field replacement. NPN-NC, 3-wire is specific, and cable leads lock in the termination style from the start.
It fits straightforward industrial metal sensing in dirty, washdown-prone areas. IP67 and IP69K, a nickel-plated brass body, and a threaded M18 cylinder point to fixed mounting on machinery, not loose fixture sensing on a bench. The -40°C to 70°C operating temperature range is broad enough for cold starts and warm enclosures, but it is still a boundary, not permission to ignore local heating or cable routing.
Can you buy it for a running line?
Can you buy it now? Not from stock here. Quantity is 0, and it is listed in bulk. Reserve any found inventory for existing production only.
The missing details are exactly the ones that close the review
The weak point is what is absent, not the headline spec set. You get the body style, sensing distance, output type, supply range, and ingress ratings, but the listing stops before the details that decide whether a control cabinet and a maintenance team will actually like living with it over time.
There is no pinout beyond NPN-NC, 3-wire, so wiring compatibility does not close from this page alone. There is no dimensional drawing beyond threaded M18 cylinder, which leaves thread length, body length, and sensing-face geometry unresolved. There is no cable detail beyond cable leads, so bend, jacket, and conductor information remain open.
The electrical gaps matter just as much, and in practice they are often the ones that slow a replacement decision after the mechanical fit looks easy at first glance. No load current, no residual voltage, no leakage current, and no detailed switching timing are listed here. Those are the numbers that separate a sensor that merely fits the bracket from one that cleanly interfaces with the PLC input card and survives the line without nuisance calls.
View the Win-Source product page for E2A-M18KS08-WP-C2 2M.
Key Takeaways for Engineers & Buyers
- Block E2A-M18KS08-WP-C2 2M from new BOMs; lifecycle is Discontinued and stock is 0.
- Check the control input against NPN-NC, 3-wire output before touching the panel wiring.
- Confirm the target and bracket can live with 8mm sensing distance in a shielded M18 body.