Omron E2A-M18KS08-WP-C2 5M discontinued sensor verdict

E2A-M18KS08-WP-C2 5M Omron product image

10V to 32V supply, 8mm shielded inductive range, M18 threaded body, -40°C to 70°C limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUC 8MM CYL 5M CBL
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 32V
Reported stock1 pcs reported — confirm on RFQ

Not for new builds

Do not design this in.

Lifecycle is marked Discontinued, and the conflict between EOL and Discontinued does not soften that call; it only reinforces the conservative reading. For a running line, treat it as a sustaining-only buy. Listed stock is 1, so even that case needs a narrow immediate use plan rather than open demand. EU RoHS compliance is still useful, but it does nothing to solve availability.

32V sets the rail ceiling, not the control scheme

32V is the ceiling.

The 10V to 32V range tells you whether it can sit on the machine rail, but not output current, voltage drop, or PLC input compatibility beyond NPN-NC, 3-Wire.

8mm and 500Hz define where it belongs

8mm is short reach, and that decides placement first.

This sensor fits close-in metal target detection where a shielded inductive face and an M18 threaded cylinder already match the mechanics, not jobs that need more reach or loose mounting tolerance. The 500Hz response frequency matters for moving targets and part-presence checks, but it is still only one line item, and without switching current or load detail it does not settle the interface question by itself.

Environmental and mechanical limits finish the picture. IP67 and IP69K indicate the enclosure can handle washdown and dirt, while -40°C to 70°C sets the ambient operating window as a ceiling, not a promise about self-heating or cable life in a crowded panel. Nickel-plated brass points to a conventional industrial body. The fixed 5M cable lead helps when the sensor sits far from the I/O block, but it works against builds that depend on field-replaceable connectors or tight cable routing.

The real blocker is supply, not sensing

Availability is the constraint.

With stock shown as 1 and lifecycle at Discontinued, this is a line-support problem before it is an engineering choice. Reserve E2A-M18KS08-WP-C2 5M only for an existing machine that already expects this exact NPN-NC, 3-Wire behavior and M18 cable format.

What the listing still doesn't answer

The weak point is electrical detail.

The listing does not give output current, leakage current, voltage drop, pinout or wire assignment, or a mechanical drawing beyond Cylinder, Threaded - M18. Those details close a control-panel review because they determine PLC input loading, fault behavior, and whether the body, thread length, and cable exit fit the bracket already in place.

View the Win-Source product page for E2A-M18KS08-WP-C2 5M.

Key Takeaways for Engineers & Buyers

  • Freeze E2A-M18KS08-WP-C2 5M out of new BOMs; lifecycle is Discontinued.
  • Check controller input logic against NPN-NC, 3-Wire before any last-time sustaining buy.
  • Confirm the machine really needs 8mm shielded sensing and a 5M cable lead set.