10V to 32V supply, 16mm range, M18 body, and -40°C to 70°C limits shape the fit
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 16MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: PNP-NC/NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Discontinued is the problem, not the sensing spec
The weak point comes first: E2A-M18LN16-M1-B3 is discontinued, and the lifecycle fields also show an EOL signal. That settles the new design question. For a machine already built around this exact sensor, the listed 16mm sensing distance, M18 threaded body, and PNP-NC/NO 3-wire output explain why it was a workable industrial choice when current, but none of that changes the lifecycle stop.
Only 1 unit is listed, so treat E2A-M18LN16-M1-B3 as a sustaining-only buy for an installed base, not a part to standardize across a new panel or machine family. EU RoHS compliance clears one paperwork issue, yet it does nothing to reduce supply risk.
The electrical limits are ordinary; the package fit is not
Don’t design it in.
The 10V to 32V supply range answers rail compatibility and not much more. It places the sensor on common industrial DC rails within that window, but it says nothing here about output load capability, voltage drop, or how much margin disappears in cable loss. The -40°C to 70°C operating temperature is also a ceiling and floor, not a promise that any enclosure location will work once local heat around the sensor body is counted.
The more design-specific facts are mechanical and functional. A 0.630 inch 16mm sensing distance sets bracket and target geometry, while the unshielded construction makes nearby metal and mounting details more sensitive than they would be with a shielded barrel. Get that wrong and the field symptom is nuisance detection.
Best fit is an existing M18 machine sensor position
16mm is the decisive figure.
That sensing distance, paired with a Cylinder, Threaded - M18 body and connector termination, puts E2A-M18LN16-M1-B3 in straightforward industrial presence sensing where the machine already expects an M18 inductive barrel and a 3-wire PNP output. IP67 and IP69K broaden the environmental fit for washdown or dirty equipment, and the nickel-plated brass body matches hard-mounted factory hardware rather than light-duty fixtures.
It does not belong in a new control design that still has open questions on mounting metal effects, output loading, or timing margin. The 400Hz response frequency is a listed ceiling on switching speed expectations, but by itself it is not enough to clear fast part tracking or edge-critical counting.
Buy only to bridge an installed base
Wrong for a rollout. Acceptable as a stopgap.
With 1 unit listed and E2A-M18LN16-M1-B3 already discontinued, the sensible move is to use it only to keep an existing machine running while migration work is underway.
The missing details are the ones that close the real review
400Hz is listed. That number alone does not close the job.
What is missing around it is exactly why E2A-M18LN16-M1-B3 stays in the sustaining-only bucket. There is no pinout detail for the connector, and that matters because PNP-NC/NO, 3-wire identifies the output style without giving the exact wiring assignment that has to land in the cabinet. There is no drawing beyond Cylinder, Threaded - M18, so bracket stack-up, thread length, and sensing-face geometry remain open. There is also no output current figure, leaving load selection and PLC input assumptions unresolved, and no switching timing detail beyond the 400Hz response frequency, so the edge behavior that decides whether a fast target is counted cleanly or missed is still unknown.
One service gap stands out too: no cable or connector mating detail is listed, only Connector. On a running line, that omission can delay a repair longer than the sensing distance ever will.
View the Win-Source product page for E2A-M18LN16-M1-B3.
Key Takeaways for Engineers & Buyers
- Block new BOM releases for E2A-M18LN16-M1-B3; lifecycle is Discontinued.
- Reserve the single listed unit for failure analysis or a line-down spare, not qualification work.
- Check the machine rail against the 10V to 32V supply window before touching panel wiring.