Omron E2A-M18LN16-WP-B1 5M discontinued sensor

E2A-M18LN16-WP-B1 5M Omron product image

10V to 32V supply, 16mm inductive range, M18 threaded body, -40°C to 70°C limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCTIVE 16MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 32V
Reported stock1 pcs reported — confirm on RFQ

Wrong for new builds, still usable in a running machine

Don’t start a new design with this sensor. The lifecycle is Discontinued, the notes also carry an EOL signal, and the listed stock is 1, so it is a sustaining-only part before electrical fit even enters the discussion.

It still has a place in an existing production line or field repair that already expects an unshielded inductive sensor with a 0.630" (16mm) sensing distance, PNP-NO 3-wire output, and cable-lead termination in a threaded M18 cylinder. EU RoHS is compliant, but that does not change the lifecycle problem.

32V is the rail ceiling; 400Hz is the motion ceiling

32V is the supply ceiling. The listed 10V ~ 32V range puts it on common industrial sensor rails inside that window, but this page says nothing about current draw, output load, or surge behavior.

The other hard limit is 400Hz. That figure sets the upper bound on target event rate before detection becomes the risk, so this sensor fits moderate-speed position and presence sensing, not machines where missed transitions turn into scrap or nuisance stops. The -40°C ~ 70°C operating temperature and IP67, IP69K ingress ratings broaden the installation envelope, but they do not answer switching speed or output loading on their own.

That points it at washdown metal sensing, with one big caveat

So the caveat is mechanical. The sensor is unshielded in a Cylinder, Threaded - M18 package, and the 0.630" (16mm) sensing distance depends on a mounting condition with clearance around the face; if nearby metal crowds it, this listing gives no correction data.

The rest of the fit is straightforward: nickel-plated brass body, cable leads, LED indicator, and IP67, IP69K protection suit industrial equipment where the sensor stays mounted and gets washed, sprayed, or knocked around. It does not belong in a compact manifold or dense fixture where a flush-mounted geometry is mandatory, and it remains a poor choice for any fresh platform because the mechanical fit can be right while the lifecycle is already dead.

The stock problem is immediate, and the datasheet gaps are real

Only 1 unit is listed. That is the weak point, and it drives the buy decision before any technical nuance does.

If this sensor is already on a machine, treat that single piece as a stopgap for service or a line-down event, not as coverage for a build plan. Box packaging helps handling. It does nothing for continuity when the lifecycle is Discontinued and quantity is effectively gone.

The missing details are concrete and they matter. The structured specs do not state cable length even though the part number E2A-M18LN16-WP-B1 5M says 5M, and they do not provide the pinout or wire color function needed to close installation without the full datasheet. Output current capability, current consumption, and load detail are also absent, so PLC input compatibility and output stress cannot be closed from this page alone. For a sensor, those are deciding points because they determine whether the machine input sees a clean signal or a field failure.

View the Win-Source product page for E2A-M18LN16-WP-B1 5M.

Key Takeaways for Engineers & Buyers

  • Block new BOM releases on E2A-M18LN16-WP-B1 5M; lifecycle is Discontinued.
  • Reserve the 1 listed unit for service stock or a line-down repair only.
  • Check machine timing against the 400Hz response limit before using E2A-M18LN16-WP-B1 5M in an existing build.