10V to 32V supply, 16mm sensing, M18 threaded body, -40°C to 70°C, IP67/IP69K
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 16MM CYL |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: NPN-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Can you still buy this for a real build?
Can you put this into a real build? Not for a new one.
Only existing production has a case, and even that case is thin. E2A-M18LN16-WP-C1 2M is marked Discontinued, while a separate lifecycle field calls it EOL, and both signals point to the same conclusion: there is no credible path to new design-in.
Availability is the immediate problem. Stock is listed as 1 and the package is Bulk, which does not support a fresh release, a pilot run, or any line that needs repeatable replenishment over time. Keep E2A-M18LN16-WP-C1 2M only where the machine is already qualified around this exact sensor and one unit can cover service exposure or a short sustaining gap. EU RoHS compliance is listed, but that doesn't change the sourcing risk.
The weak point is lifecycle; the electrical window is straightforward
The weak point comes first: lifecycle is already against you. After that, the operating window is at least clear.
The 10V ~ 32V supply range tells you whether E2A-M18LN16-WP-C1 2M fits the existing sensor rail, but it does not answer output loading, surge behavior, or brownout tolerance because those figures are not listed. The -40°C ~ 70°C operating temperature is the ambient limit for the sensor itself. It is not a cabinet or cable-bundle rating.
Then there is the 400Hz response frequency. That figure sets the switching-speed ceiling in the listing, so it rules out faster event detection while leaving timing margin under cable length, target size, and installation geometry unanswered.
Wrong for flush mounting, right for wet industrial sensing
Wrong for tight flush mounting. This is an unshielded inductive sensor in a Cylinder, Threaded - M18 body, so the mechanical fit has to respect the field shape that comes with an unshielded build.
Where it does fit is ordinary machine sensing that needs a 0.630" (16mm) reach, an NPN-NO, 3-Wire output, and cable leads instead of a connectorized body. The nickel-plated brass housing and IP67, IP69K ingress ratings point it toward washdown-prone or dirty equipment where the sensor body takes abuse. Good fit for industrial metal-target detection; poor fit for any program that still needs sourcing flexibility.
16mm is useful, but the missing details still matter
16mm is enough to start bracket and target-spacing work, but not enough to close it.
The listing does not give cable length beyond the part-number suffix, pinout or wiring color code, mechanical drawing, load current, or voltage drop for the NPN-NO output stage. Those omissions matter. They determine PLC input compatibility, harness reuse, and whether the installed sensor actually clears the surrounding metalwork. For E2A-M18LN16-WP-C1 2M, those are the details the full datasheet still has to settle.
View the Win-Source product page for E2A-M18LN16-WP-C1 2M.
Key Takeaways for Engineers & Buyers
- Lock the control rail to the listed 10V ~ 32V window before keeping E2A-M18LN16-WP-C1 2M on a running line.
- Check the machine target and bracket against the 0.630" (16mm) sensing distance and unshielded M18 body.
- Reserve the single listed unit only for service or line-down coverage; this is a discontinued sensor.