Omron E2A-M18LS08-WP-B1 2M discontinued, sustaining only

E2A-M18LS08-WP-B1 2M Omron product image

10V to 32V supply, 8mm shielded inductive range, M18 threaded body, -40°C to 70°C ceiling

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 8MM CYLIND
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 500Hz; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

8mm range doesn’t save a discontinued sensor

8mm sets the sensing position. It does nothing for supply risk.

E2A-M18LS08-WP-B1 2M is discontinued, stock is 0, and the lifecycle conflict between EOL and Discontinued still ends at the same conclusion: no new design-in.

For an existing production line, the fit is much narrower. The listed 0.315" (8mm) sensing distance, shielded construction, and M18 threaded cylinder point to close-in metal detection in a fixed industrial mount, not a loose retrofit where extra reach could mask alignment drift. EU RoHS is compliant. Lifecycle is the blocker.

Can you actually buy it now?

Can you get it now? No.

Quantity is 0, and bulk packaging changes nothing when the part itself is discontinued. Treat E2A-M18LS08-WP-B1 2M as sustaining-only and freeze any build that still depends on fresh supply.

The real fit is set by wiring, rail, and environment

The weak point is supply. The stronger point is that the remaining specs still define the machine position it was built for, and just as clearly, where it does not belong.

The 10V ~ 32V supply is a rail limit, not an operating assumption for every cabinet. That closes one decision fast: this sensor belongs in low-voltage industrial DC systems that stay within that window. By itself, though, that range does not settle output current, voltage drop, or PLC input compatibility, so the PNP-NO, 3-Wire output still has to match the receiving input stage and wiring convention before anyone treats it as a drop-in replacement.

Mechanical fit and environmental exposure narrow it further. Cylinder, Threaded - M18 with a shielded inductive face and 0.315" (8mm) sensing distance points to flush-style mounting in metalwork where detection distance is intentionally modest and repeatable, while IP67, IP69K and -40°C ~ 70°C set the ceilings for ingress protection and ambient exposure. Those ratings suit washdown or dirty equipment, but they do not answer cable flex life, chemical resistance, or sensing stability across temperature. The 500Hz response frequency is the speed limit that matters when the target is moving fast; miss that constraint and missed counts show up long before the housing does.

The missing details are the ones that close the review

The constraint is incomplete electrical detail. The listing does not give the cable pinout or lead color function, and that matters immediately on a 3-wire PNP-NO sensor.

It also omits load current, voltage drop, and current consumption, so you cannot close the PLC input budget from this page alone. No body drawing or threaded length is shown either, leaving panel depth and bracket fit unresolved even though the package says M18.

View the Win-Source product page for E2A-M18LS08-WP-B1 2M.

Key Takeaways for Engineers & Buyers

  • Stop new BOM releases on E2A-M18LS08-WP-B1 2M; lifecycle is Discontinued and stock is 0.
  • Check the control input against PNP-NO, 3-Wire before touching harness or PLC wiring.
  • Hold mounting to shielded 8mm sensing in an M18 threaded body; don't assume longer range.