Omron E2A-M30LN30-WP-B2 2M discontinued, sustaining only

E2A-M30LN30-WP-B2 2M Omron product image

10V to 32V supply, 30mm inductive sensing, M30 threaded body, -40°C to 70°C, IP67 and IP69K

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCTIVE 30MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

Discontinued is the problem, not the sensor body

The weak point comes first: it is discontinued, and listed stock is 0. That rules it out for new design-in.

For existing machines, EU RoHS compliance and the defined mechanical format still help while you lock down field support.

Wrong for fast detection, right for rugged machine sensing

High-speed work is the wrong fit. A 100Hz response-frequency ceiling puts this sensor out of bounds for fast part tracking, encoder-like event counting, or stations where missed transitions turn into yield loss.

It fits slower industrial presence sensing in rough service. The 1.181" (30mm) sensing distance gives useful stand-off for a large threaded inductive body, but the unshielded construction still matters because distance alone does not settle the mounting call; surrounding metal geometry can still change the result. IP67 and IP69K, a nickel-plated brass body, and a -40°C to 70°C operating range point more toward washdown and outdoor cabinet-adjacent duty than dense tooling where every millimeter around the barrel is already claimed.

Electrical fit is simple, but only within these ceilings

Electrically, it is narrow.

The sensor takes 10V to 32V supply and uses a PNP-NC, 3-Wire output. That settles one question and leaves another open: it can sit on common industrial DC rails within that 10V to 32V window, but the listing does not give output current, voltage drop, or leakage, so PLC input compatibility is still unresolved. PNP-NC also fixes machine-level logic behavior; get that wrong and the problem shows up as an inverted safe state, not a minor software annoyance. Cable leads suit sealed installations, yet connectorization and field-replacement time remain open because cable length beyond the 2M model suffix is not broken out here.

The real blocker is availability, so treat it as a line hold risk

Zero stock is the constraint.

Stack that on a discontinued lifecycle and the result is a sustaining-only part for installed equipment, not something to leave on an open production BOM.

Freeze demand against actual service need, then remove it from any forward build that has not locked hardware. The package field says Box, but that has no weight when there is nothing to ship. The practical risk is direct: one failed sensor can stop a machine, and this channel shows no listed inventory to absorb it.

View the Win-Source product page for E2A-M30LN30-WP-B2 2M.

The missing details are exactly the ones that close mounting and I/O review

30mm is useful, but not sufficient.

For E2A-M30LN30-WP-B2 2M, the missing items are the ones that decide whether the sensor drops into a real bracket and a real input card without surprises.

The listing does not include a pinout or lead-color assignment, and that matters immediately with a PNP-NC, 3-Wire sensor because wiring mistakes create false state reporting at power-up. It also does not include a mechanical drawing, so thread length, body length, nut stack, and sensing-face geometry remain open. On an unshielded inductive sensor, that drawing is what tells you whether nearby metal will steal the margin you thought the 1.181" (30mm) distance bought you.

The electrical gaps are just as important. There is no output current rating, no residual voltage, and no leakage figure, so input loading and off-state behavior stay unknown. E2A-M30LN30-WP-B2 2M may still work in an existing machine, but those omissions mean wiring and interface closure still depend on the datasheet.

View the Win-Source product page for E2A-M30LN30-WP-B2 2M.

Key Takeaways for Engineers & Buyers

  • Stop new releases on E2A-M30LN30-WP-B2 2M; lifecycle is Discontinued and stock is 0.
  • Check the control input against PNP-NC, 3-Wire before touching the harness or PLC card.
  • Use 100Hz as the switching ceiling; fast target counting will outrun this sensor.