Omron E2A-M30LN30-WP-C2 2M discontinued sensor

E2A-M30LN30-WP-C2 2M Omron product image

10V to 32V supply, 30mm range, M30 threaded body, -40°C to 70°C, and a discontinued lifecycle

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBox
Core functionSENSOR PROX INDUCTIVE 30MM CYL
Key electrical rangeOperating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 100Hz; Voltage - Supply: 10V ~ 32V
Reported stock0 pcs reported — confirm on RFQ

Can you still buy this for a running line?

Can you still get it if a machine is already built around it? Only in that sustaining-build sense. E2A-M30LN30-WP-C2 2M is marked Discontinued, and the wording conflict is only whether you call it EOL or Discontinued; neither supports new design-in.

The practical constraint is stock: 0 listed. That makes this a part to support existing production, not one to leave on an open BOM. EU RoHS compliance is listed, so compliance is not the issue here. Lifecycle and availability are.

The real limits are range, speed, and the rail window

The constraint is the numbers themselves. A 30mm sensing distance, 100Hz response frequency, and 10V to 32V supply window quickly decide whether the sensor fits the machine cycle and control rail.

That 30mm range tells you how far the sensor can stand off from the target in a dirty mechanical environment, but it does not answer switching accuracy, hysteresis, or target dependence. Those details are not shown. The 100Hz figure is a hard ceiling; if the event rate pushes past it, missed transitions arrive before ingress protection or body material become the real issue.

The supply range settles one integration question: it belongs on low-voltage industrial control rails within 10V to 32V. It does not settle output loading, voltage drop, or current budget, because those values are not listed. The -40°C to 70°C operating range also sets a clear boundary. Cold service is plausible, but 70°C remains the upper limit, not an everyday cabinet condition.

Wrong for tight flush mounting

Wrong for tight flush mounting. It is unshielded, so this is not the sensor to bury in metal with no clearance. It fits builds that already expect an inductive, NPN-NC, 3-Wire sensor in a Cylinder, Threaded - M30 body with cable leads and an LED indicator.

The missing details are the ones that close risk

Not enough is shown.

Don’t stretch this listing. The missing items that actually close release risk are the pinout for the cable leads, the mechanical drawing around the M30 body, and the switching detail behind the 100Hz figure.

The load-side electrical limits are missing too, especially output current and residual voltage for the NPN-NC, 3-Wire output. Without them, PLC input compatibility and fault behavior stay open questions. IP67 and IP69K speak to enclosure survival, not wiring behavior or output limits.

View the Win-Source product page for E2A-M30LN30-WP-C2 2M.

Key Takeaways for Engineers & Buyers

  • Freeze E2A-M30LN30-WP-C2 2M out of new BOMs; lifecycle is Discontinued and stock is 0.
  • Check controller input logic against NPN-NC, 3-Wire before touching an existing panel design.
  • Keep mounting clear around the 30mm unshielded face; shielding is absent and the body is M30 threaded.