10V to 32V supply, 4mm range, M8 threaded body, -40°C to 70°C limits, PNP-NC 3-wire output
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 4MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Can you still buy this for a running line?
Can you still get it for production support? Yes, but only for an existing line. The lifecycle record carries EOL, one product-status field still says Active, and stock is 0 now.
That conflict is the real story. It blocks new design-in and raises the chance that a service build stops on availability before it reaches the panel. RoHS is listed as EU RoHS, so compliance is not the issue here; lifecycle risk and zero inventory are.
Not for flush mounting; fine where 4mm is enough
Wrong for flush mounting. The body is explicitly unshielded, and the listed sensing distance is 0.157" (4mm), so this sensor fits installations where the target can be brought close and the mounting geometry is controlled.
The rest is straightforward: inductive proximity sensing in a threaded M8 stainless-steel cylinder with cable leads and a PNP-NC 3-wire output. That suits machine builds already set up for a compact cylindrical sensor and a normally closed PNP signal. Get the output logic wrong, and the problem shows up during commissioning.
10V to 32V is the rail ceiling that decides fit
10V to 32V sets the fit. It answers nominal control-rail compatibility, but output loading, leakage, and interface timing stay open because those figures are not listed.
The environmental limits are useful, not complete
The weak point is missing detail. IP67 and IP69K, along with a -40°C to 70°C operating range, put it in washdown and dirty industrial spaces, and the stainless-steel body supports that reading.
Those numbers are still boundaries, not a full installation answer. They do not cover cable bend limits, connector options, or how sensing distance shifts across temperature. For exposed machinery, the protection ratings keep it in consideration, but they do not finish the mounting decision.
What the listing still doesn't tell you
Key details are missing.
The first gap is wiring. There is no pinout or wire-color assignment, and that is the first detail needed to land a PNP-NC 3-wire sensor into a cabinet without rework.
Electrical detail is thin as well. Response frequency is 1kHz, but there is no load current figure, no voltage drop or residual voltage on the output, and no current consumption figure, so the PLC input budget and fault-state behavior remain open.
Mechanical definition also stops early. You get Cylinder, Threaded - M8 and cable leads, but no drawing, no threaded length, and no body dimensions beyond the M8 callout, which leaves bracket fit and wrench clearance unresolved for anyone trying to release hardware with confidence.
One more omission matters in production: there is no approval or qualification field beyond EU RoHS, so any requirement tied to a named industry standard stays open.
View the Win-Source product page for E2A-S08KN04-WP-B2 2M.
Key Takeaways for Engineers & Buyers
- Freeze E2A-S08KN04-WP-B2 2M out of new BOMs; lifecycle is EOL and stock is 0.
- Check the control input against PNP-NC, 3-Wire before touching the harness or PLC card.
- Use the 4mm sensing distance and unshielded M8 body to confirm mechanical spacing at the target mount.