10V to 32V supply, 2mm sensing, M8 threaded body, -40°C to 70°C limits decide where it still fits
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 2MM CYLIND |
| Key electrical range | Operating Temperature: -40°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Sustaining only, and even that is tight
Do not design this in.
The lifecycle picture conflicts, but the conservative read is still EOL because both the lifecycle record and the listed Lifecycle Status say EOL while Product Status says Active. That settles the new-design question. For existing production, it can still hold a place if your machine already expects an NPN-NC, 3-Wire inductive sensor in a threaded M8 body, but stock is 0, so leaving it unresolved on a live BOM is a sourcing mistake. EU RoHS compliance removes one paperwork issue, not the lifecycle risk.
The 2mm range is the real constraint
The weak point comes first: 0.079" (2mm) sensing distance leaves almost no mechanical slack. The upside is the shielded construction, which suits tight metal surroundings where an unshielded barrel would be harder to place.
A 10V to 32V supply range gives it room on common industrial DC rails, but it does not settle PLC input compatibility on its own. Response frequency is 1.5kHz, fast enough to matter in counting or position feedback, yet it still does not rescue a marginal target if mechanical dwell inside that 2mm field is poor. Get the geometry wrong and the field return won't look electrical at all.
So the fit is narrow but legitimate
And that narrow fit is the whole point. Compact industrial fixtures, conveyors, and tooling are where a stainless steel body, connector termination, and IP67, IP69K sealing earn their place instead of just filling out a spec line.
It is a poor match for any setup that needs generous target tolerance, because 2mm is a hard placement discipline. It is also the wrong sensor if your control scheme expects anything other than NPN-NC, 3-Wire, since that output choice sets wiring and input logic immediately. The -40°C to 70°C operating temperature range gives useful ambient headroom for plant equipment, but it remains the listed limit and does not answer enclosure hot-spot behavior.
What the listing still does not tell you
Wrong for a final release decision. Right for an early keep-or-kill call.
The listing already gives enough to reject E2A-S08KS02-M1-C2 for new work and quarantine it on sustaining builds, but it still leaves several practical checks open, and those are the ones that decide whether an existing machine can keep using it without rework.
There is no connector pinout, so wiring cannot be closed from this listing alone. There is no mechanical drawing beyond Cylinder, Threaded - M8, which leaves thread length and body proportions unresolved for bracket design. There is no load current or output electrical detail for the NPN-NC stage, so PLC input and load-interface checks stay open. There is also no switching accuracy or hysteresis figure, and with only 0.079" (2mm) sensing distance available, those missing numbers decide whether a marginal target is stable or chatters.
View the Win-Source product page for E2A-S08KS02-M1-C2.
Key Takeaways for Engineers & Buyers
- Lock the control input to an NPN-NC, 3-Wire interface before keeping E2A-S08KS02-M1-C2 on a running line.
- Check mechanical stackup against the 0.079" (2mm) sensing distance and shielded M8 threaded body.
- Reserve this sensor for washdown or exposed mounting only when IP67, IP69K and -40°C to 70°C are actual requirements.