10V to 32V supply, 20mm sensing, M30 threaded body, -25°C to 70°C, and a discontinued lifecycle
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 20MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 80Hz; Voltage - Supply: 10V ~ 32V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Not for new builds
Don’t use it. E2A3-M30KS20-WP-C2 2M is marked Discontinued, and one lifecycle field also calls it EOL, so this is a sustaining-only part. EU RoHS compliance does not change that.
Can you still buy enough to keep a line moving?
Is there enough stock to matter? No. The listing shows 1 unit, which makes E2A3-M30KS20-WP-C2 2M a stopgap for a field failure or one stalled station, not a real sourcing path for production.
The fit question comes next. Supply is 10V to 32V, broad enough for common industrial control rails, but that alone does not settle the interface because the listing does not give output current, voltage drop, or load drive. Output type is NPN-NC, 3-wire, and that detail matters more than the wide supply range because a sensor can wire neatly into a cabinet and still hand the controller the wrong state if the input expectation is off.
Mechanical fit is just as specific. Sensing distance is 0.787" (20mm), and the sensor is shielded in a Cylinder, Threaded - M30 body, so that number sets bracket geometry and target approach as much as it sets detection range. Response frequency is 80Hz, a ceiling rather than an operating target, which keeps it in slower position and presence checks instead of fast counting or tight motion timing where missed transitions turn into ugly intermittent faults.
The package and limits point to fixed industrial mounting
The constraint is physical integration. This inductive, shielded sensor uses a threaded M30 cylinder with cable leads and a nickel-plated brass body, so it fits machine frames, guards, and metal fixtures built for a large barrel sensor.
Environmental limits are clear enough to be useful. IP67 and IP69K support washdown and dirty enclosures, while -25°C to 70°C is the ambient ceiling and floor from the listing. The 20mm sensing distance gives some mechanical standoff for metal target detection, but the page says nothing about target material dependence or mounting detail beyond shielded construction, so a simple bracket swap is not something to assume will leave detection unchanged.
What the listing still doesn’t answer
And that leaves the real integration gaps. The listing does not give pinout or lead assignment, a mechanical drawing, load current, output electrical limits, or switching timing detail beyond the 80Hz response figure.
Those omissions matter more than another recap. Without the drawing, bracket and jam-nut fit stay open. Without lead assignment and output limits, the controller interface review stays open too.
View the Win-Source product page for E2A3-M30KS20-WP-C2 2M.
Key Takeaways for Engineers & Buyers
- Block new BOM adds; E2A3-M30KS20-WP-C2 2M is discontinued.
- Check controller input for NPN-NC, 3-wire compatibility before touching a running line.
- Reserve the single listed unit only for a line stop or service spare.