10V to 30V supply, 5mm range, M12 threaded body, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
10V to 30V decides the control side first
10V to 30V is the first gate. That supply range puts E2B-M12KN05-M1-C2 on common industrial DC rails, but it still leaves output loading, startup behavior, and noise margin open because the listing stops at the rail window and output type.
The other number that drives the decision is 0.197" (5mm) sensing distance. In a Cylinder, Threaded - M12 body, that is the reach ceiling you package around, not a promise that every target and mounting condition will trip at the same point. Get the mechanics wrong and the result is simple: missed detection.
The output and body style narrow the fit fast
And the fit gets narrower once you read NPN-NC, 3-Wire with Connector termination. This is not a generic drop-in sensor for any PLC input card; it belongs where an NPN sinking, normally closed signal is already expected, or where the input stage can be wired for it without extra interface work.
Unshielded matters too. In a threaded M12 barrel, nearby metal and mounting geometry become part of the sensing problem. The nickel-plated brass body and IP67 rating make the mechanical package credible for wet industrial mounting, but they do not settle the electrical side.
The hard stop is availability
Availability is the constraint. Stock quantity is 1, so this supports evaluation or a one-off service need, not a real build. Active lifecycle doesn't change that.
View the Win-Source product page for E2B-M12KN05-M1-C2.
What would close the review fastest
Can you release it now? Not cleanly. The missing details are the ones that decide integration effort.
Start with the absent output-current limit. NPN-NC, 3-wire tells you the logic style, but not what load the sensor can actually switch. Then look at the missing pinout or connector wiring; Connector termination is named, but the contact assignment is not, and that is where commissioning mistakes happen.
The mechanical side is incomplete as well. You have Cylinder, Threaded - M12 and unshielded, but no drawing, no thread length, and no mounting dimensions to show where the sensing face sits relative to the hardware stack. Response frequency is 800Hz, which helps, but there is no switching diagram or timing detail to show how that limit is defined in practice.
Then there is the compliance issue. One field says RoHS Compliant, another says RoHS Non-Compliant. Clear that before E2B-M12KN05-M1-C2 goes onto any build that requires EU RoHS.
View the Win-Source product page for E2B-M12KN05-M1-C2.
Key Takeaways for Engineers & Buyers
- Match the control input to NPN-NC, 3-wire before releasing E2B-M12KN05-M1-C2.
- Check the 5mm sensing distance against target metal and mounting around the unshielded M12 body.
- Resolve the RoHS conflict and secure more than 1 piece before putting E2B-M12KN05-M1-C2 on a build.