10V to 30V supply, 5mm inductive range, M12 threaded body, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 5MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 0 pcs reported — confirm on RFQ |
Zero stock is the weak point; the fit is otherwise clean
The weak point comes first: listed quantity is 0, so you can't count on E2B-M12KN05-WP-B2 2M for an immediate line pull. The stronger read is lifecycle. Status fields show Active, which keeps it in play for new design-in rather than pushing it into a sustaining-only corner.
Fit turns on the actual interface. PNP-NC, 3-Wire output, 0.197" (5mm) sensing distance, and a Cylinder, Threaded - M12 body define where this sensor belongs, and that combination lines up with compact industrial position sensing where the control side already expects a normally closed PNP signal and the mechanics are built around an M12 barrel. The 10V ~ 30V supply range gives room across common control rails, but load compatibility is still open because no output current limit is listed here.
Paperwork is the other snag. One field says RoHS Compliant and another says RoHS Non-Compliant, so EU RoHS status stays unresolved until the manufacturer declaration is matched to E2B-M12KN05-WP-B2 2M.
The electrical limits narrow the application fast
This is narrow.
The 10V ~ 30V supply range is the operating window, which places E2B-M12KN05-WP-B2 2M on low-voltage industrial rails rather than direct mains interfaces. The 800Hz response frequency is a ceiling, and if the event rate goes past it, missed detection is the failure mode that matters. The 0.197" (5mm) sensing distance is the placement constraint, especially with an unshielded sensor, because nearby metal and mounting geometry will decide how usable that nominal reach is.
Environment closes out the picture. IP67 and -25°C ~ 70°C make it reasonable for washdown splash and ordinary factory temperature swings, but those are still limits, not a pass to ignore enclosure heat or cable routing.
Mechanical envelope matters more than the LED
The real constraint is physical integration. A threaded M12 cylinder in nickel-plated brass with cable leads mounts easily on brackets, guards, and actuator stations, but it is the wrong choice where a connectorized sensor is needed for fast swap-out or where panel depth is tight behind the mounting face.
Unshielded construction drives the other placement call. It works when the sensing face has some breathing room from surrounding metal and when a 5mm trip point covers target variation. It is a poor fit for cramped fixtures that need flush mounting behavior, because the listing does not claim shielding.
What would close the open questions
What is still missing? Output current, pin or lead assignment, and a mechanical drawing. Those decide PLC input loading, cabinet wiring, and whether the bracket clears the target and locknuts.
View the Win-Source product page for E2B-M12KN05-WP-B2 2M.
Key Takeaways for Engineers & Buyers
- Match the control input to PNP-NC, 3-wire before releasing E2B-M12KN05-WP-B2 2M.
- Check the machine bracket against the M12 threaded cylinder and the 0.197" (5mm) sensing distance.
- Place a buy only after confirming stock, because listed quantity for E2B-M12KN05-WP-B2 2M is 0.