Omron E2B-M12KN08-WP-C2 5M for new design-in

E2B-M12KN08-WP-C2 5M Omron product image

10V to 30V supply, 8mm range, unshielded M12 body, -25°C to 70°C limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 8MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 800Hz; Voltage - Supply: 10V ~ 30V
Reported stock2 pcs reported — confirm on RFQ

Still a valid design-in, but only if the logic fits

And that is the real gate here: not lifecycle, but interface. The part is Active, with matching lifecycle signals and no conflict, so there is no status-based reason to avoid new design-in. EU RoHS stays a clause, not a project.

The catch is the output. E2B-M12KN08-WP-C2 5M is NPN-NC, 3-Wire, and that settles controller compatibility faster than the mechanical description does. If your input card expects that logic, it stays in play. If it expects different output behavior, Active status doesn't help.

Can you actually buy this for a running line?

Can you actually cover production with stock quantity 2? No. That answer matters more than the Active lifecycle, because a healthy part with two pieces on hand can still stop a line.

For fit, the useful numbers are 0.315" (8mm), 10V ~ 30V, 800Hz, and -25°C ~ 70°C. The 0.315" (8mm) sensing distance puts it in short-range metal detection, not layouts that need extra stand-off for bracket tolerance or target wander. Because the body is unshielded in a Cylinder, Threaded - M12 format, mounting geometry is not a side issue; nearby metal can decide whether that 8mm ceiling is usable in the machine.

The 10V ~ 30V supply range is a limit band, not a promise about every control cabinet. It places E2B-M12KN08-WP-C2 5M on common industrial rails, but it does not answer input current, voltage drop, or output loading because those numbers are not listed here. The 800Hz response frequency is the other hard filter: fast enough for many position and presence checks, not a blank check for every high-speed count or tight timing job. Confirm that the machine event rate sits comfortably inside that limit, then secure supply before release.

8mm is the number that decides the mechanics

8mm is the mechanical ceiling that shapes the use case.

IP67 and nickel-plated brass help with plant-floor exposure, but they do not widen the sensing envelope.

The missing electrical details are the real review gap

The weak point is missing detail, not lifecycle. This listing is enough to shortlist E2B-M12KN08-WP-C2 5M, but not enough to close the electrical and installation review.

What is absent matters: no pinout or wire assignment for the cable leads, no drawing beyond Cylinder, Threaded - M12, no load current figure for the NPN-NC output, and no switching detail beyond 800Hz. Those are the gaps that create field mistakes, especially when a sensor looks mechanically familiar. Get the full datasheet before freezing wiring, panel input selection, or bracket clearances.

View the Win-Source product page for E2B-M12KN08-WP-C2 5M.

Key Takeaways for Engineers & Buyers

  • Match the PLC input to NPN-NC, 3-wire before releasing E2B-M12KN08-WP-C2 5M.
  • Reserve it for builds that can live with 0.315" (8mm) sensing distance and an unshielded M12 body.
  • Do not count on immediate volume coverage; stock is 2 and the part ships in Bulk with cable leads.