Omron E2B-M12KS02-WP-C2 2M active, but check compliance

E2B-M12KS02-WP-C2 2M Omron product image

10V to 30V supply, 2mm shielded inductive range, M12 threaded body, -25°C to 70°C limits

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

2mm decides whether this sensor belongs at all

2mm makes the decision. That sensing distance puts this shielded inductive sensor in tightly controlled metal-detection positions, not in mounts where bracket drift, target runout, or buildup already consume the gap.

The rest of the listing points the same way. The body is Cylinder, Threaded - M12 in nickel-plated brass, with cable leads and an LED indicator, so this is a straightforward machine-mounted sensor rather than a board-level device. Active lifecycle supports new design-in, but the RoHS fields conflict, so Omron E2B-M12KS02-WP-C2 2M should not clear compliance review on assumption alone.

Not for loose mechanics; fine for compact metal sensing

Loose mechanics are where this goes wrong first. A 2mm sensing distance and shielded construction rule out applications that need generous target clearance or side-field reach, even before control wiring enters the picture.

It fits compact industrial metal sensing in an M12 threaded mount, especially where IP67 and a -25°C to 70°C operating range match the machine envelope. The 10V to 30V supply range gives flexibility across common control cabinets, but it does not answer input compatibility by itself; the output is NPN-NC, 3-wire, and that decides whether the PLC input scheme is native or awkward. Get that wrong and the problem isn't subtle.

1.5kHz is the real performance limit to read first

1.5kHz is the number to read first. It is the only listed dynamic limit, and it is a ceiling, not a promise about every target, gap, and mounting condition.

Set that beside the 10V to 30V supply range and the boundaries get clearer: the sensor can live on a broad set of industrial rails, but rail fit does not answer timing fit. If the event stream already runs near the edge, this listing does not leave much room to recover the decision later, because the missing details are practical ones rather than minor omissions.

Mechanical and environmental limits matter just as much. M12 threaded packaging, shielded sensing, and IP67 point to close-in mounting on equipment that sees washdown or dust, while the -25°C to 70°C operating range is the ambient ceiling for placement, not a statement that every enclosure or cable run is safe there. Omron E2B-M12KS02-WP-C2 2M looks easy to mount, but easy mounting is not the same as forgiving sensing.

The open questions are concrete: no drawing, no pinout or lead assignment, no switching diagram, and no dimensional detail beyond M12 and the 2mm range. Those gaps decide bracket design, wiring release, and whether the 1.5kHz ceiling holds once the actual target geometry is in play.

Can you actually buy it for a build?

Can you get enough of it? Stock says 1.

Use it for a sample or a stopgap on an existing line, then secure committed supply before freezing it into a build. Bulk packaging is ordinary here; quantity is the real blocker.

View the Win-Source product page for E2B-M12KS02-WP-C2 2M.

Key Takeaways for Engineers & Buyers

  • Match the input card to the NPN-NC, 3-wire output before releasing E2B-M12KS02-WP-C2 2M.
  • Hold layout to a 2mm sensing distance; this sensor will not rescue loose target tolerance.
  • Clear the RoHS conflict before PO release; stock is 1 and the compliance fields disagree.