Omron E2B-M12LS02-WP-C2 5M for new design-in

E2B-M12LS02-WP-C2 5M Omron product image

10V to 30V supply, 2mm shielded M12 inductive sensor, -25°C to 70°C, NPN-NC 3-wire

Quick Engineering Summary

FieldValue
ManufacturerOmron
CategoryProximity Sensors - Industrial
PackageBulk
Core functionSENSOR PROX INDUCTIVE 2MM CYLIND
Key electrical rangeOperating Temperature: -25°C ~ 70°C; Output Type: NPN-NC, 3-Wire; Response Frequency: 1.5kHz; Voltage - Supply: 10V ~ 30V
Reported stock1 pcs reported — confirm on RFQ

The 2mm range is the real design constraint

The constraint is mechanical first: 0.079" (2mm) sensing distance. Small margin. That settles the fit question before the electrical one, because this shielded M12 sensor needs a target that stays very close to the face without bracket drift, stack-up, or target wobble eating the trip point.

The 10V ~ 30V supply is a compatibility window, not a statement about noise immunity or output loading, and the -25°C ~ 70°C operating temperature is a ceiling and floor for operation, not proof of outdoor survival by itself. IP67 and a nickel-plated brass body support wet industrial mounting, but the real decision still comes down to whether the machine can hold a 2mm trip point and use an NPN-NC, 3-wire output.

Can you actually buy E2B-M12LS02-WP-C2 5M now?

Can you buy it for production right now? Not really. Stock is 1, so E2B-M12LS02-WP-C2 5M works for qualification or a line stop, not for an open release.

RoHS is conflicted too: one field says RoHS Compliant and another says RoHS Non-Compliant.

That output choice narrows the PLC side fast

And that narrows the PLC side just as quickly: E2B-M12LS02-WP-C2 5M is NPN-NC, 3-wire. If the input card, safety logic, or field wiring standard expects PNP behavior or normally open logic, this is the wrong sensor.

Response frequency is 1.5kHz, so it fits fast machine sensing better than slow presence-only duty, but it still leaves open the details that decide interface behavior in practice, including load current, debounce behavior, and cable-induced edge quality. The LED indicator helps during commissioning. It does not settle interface qualification.

What the listing still does not tell you

The weak point is documentation depth. The listing identifies E2B-M12LS02-WP-C2 5M clearly as a shielded, threaded M12 inductive sensor with cable leads, but it stops short of the details that finish a release.

What is still missing is concrete: pinout detail for the 3-wire cable, the mechanical drawing behind the M12 threaded body, and the output electrical limits that determine PLC input loading and fault behavior. It also does not include a datasheet-level switching curve or installation detail around the 2mm sensing distance, where false trips and missed targets usually appear first once the bracket is already cut.

View the Win-Source product page for E2B-M12LS02-WP-C2 5M.

Key Takeaways for Engineers & Buyers

  • Lock the control input to NPN-NC, 3-wire before releasing the BOM.
  • Check the target and bracket against the 2mm sensing distance; there is little mechanical slack.
  • Reserve parts only for a named build; listed quantity is 1.