10V to 30V supply, 4mm shielded range, M12 threaded body, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 4MM CYLIND |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 1kHz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 2 pcs reported — confirm on RFQ |
Good for new builds, but stock is the real limit
Use it.
Nothing in the lifecycle status blocks a new design-in or a running line. E2B-M12LS04-WP-B1 2M is listed as Active, and RoHS is shown as compliant under EU RoHS, so the real constraint is availability, not status. Stock is 2. That covers a bench build or a service event, but not line continuity.
It fits when you want a threaded M12 inductive sensor with cable leads and already know a PNP-NO, 3-wire output matches the control scheme. Buy against near-term demand, then secure the next tranche before you freeze the BOM around E2B-M12LS04-WP-B1 2M.
The 4 mm range is a hard fit decision
And that fit starts with the sensing envelope, not the thread size. The listed sensing distance is 0.157" (4mm), which settles one decision right away: this belongs on short-gap metal detection jobs, not on brackets where target wander or stack-up already consumes several millimeters. Treat 4mm as the ceiling the listing gives you, not as working clearance.
The 10V ~ 30V supply range is the other number that drives integration. It places the sensor on common industrial DC rails inside that window, but the listing does not give output current, voltage drop, or the load the PNP stage can actually drive, and that gap matters because a sensor can switch cleanly while the PLC input still never sees a valid high. Response frequency is 1kHz, fast enough for many machine positions, but still a limit that has to match target speed and spacing rather than a blanket promise about every motion profile.
M12 threaded, shielded, and meant for tight metalwork
4mm is the whole game here. With a shielded inductive head in a Cylinder, Threaded - M12 body, the mechanical envelope and target geometry decide success before lifecycle ever enters the conversation.
That combination suits compact fixtures, end-of-stroke detection, and metal target confirmation where flush-style mounting and a narrow detection zone help more than broad reach. The nickel-plated brass body and IP67 rating support dirty industrial mounting points, while the -25°C ~ 70°C operating temperature ceiling covers ordinary plant ambient without saying anything about self-heating inside sealed tooling. E2B-M12LS04-WP-B1 2M is the wrong fit where the target is nonmetal, where the gap must exceed 4mm, or where the control input expects NPN behavior instead of PNP-NO.
The listing is thin where release work needs detail
The weak point is detail. No pinout, no cable lead assignment, no load or output-current figure for the PNP-NO stage, and no body drawing beyond M12 threaded cylinder.
Repeatability and hysteresis are also missing.
View the Win-Source product page for E2B-M12LS04-WP-B1 2M.
Key Takeaways for Engineers & Buyers
- Match the input card to the PNP-NO, 3-wire output before releasing E2B-M12LS04-WP-B1 2M.
- Hold the target gap to the 4mm sensing distance; that number is a fixed ceiling, not setup margin.
- Cover only immediate need now; listed stock is 2 and the part ships in Bulk with cable leads.