10V ~ 30V supply, 10mm sensing, M18 threaded body, -25°C ~ 70°C, 400Hz response
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 10MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NO, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
10mm reach is the real design decision
10mm decides the fit before anything else. This is an inductive, unshielded, M18 threaded cylinder with a listed sensing distance of 0.394" (10mm), so the mechanical stack-up around the target matters more than the generic fact that it is an industrial sensor.
If your bracket, guard, or target geometry was laid out around a shorter reach or a shielded barrel, this part changes the mounting problem before it solves the sensing one. The 10V ~ 30V supply range answers one interface question quickly, since it sits inside common control rails around PLC I/O, but it leaves output current, voltage drop, and load compatibility at the input card unanswered.
The PNP-NO, 3-Wire output narrows the wiring choice right away: use it where sourcing logic is expected, and rule it out where the cabinet standard is NPN. Response frequency is listed at 400Hz, and that number is a ceiling on event rate, not a promise about every target condition, especially once target size, approach angle, and installation geometry start working against the nominal sensing distance.
For a new design-in, the case is straightforward only when the mechanical envelope, the PNP-NO interface, and the line speed all line up at once. EU RoHS status does not. One field says RoHS Compliant while another says RoHS Non-Compliant, so that point stays unresolved until the manufacturer declaration is checked.
Stock is weak, though the lifecycle is not
One piece in stock is the weak point. Active lifecycle status is not.
That split matters. The record shows Active across lifecycle fields with no stated conflict, so there is no end-of-life signal in view. For a new build, that supports design-in. For a running line, the immediate constraint is simpler and harsher: quantity is 1, and that will not cover a maintenance spike, a pilot run, or a line stop caused by a damaged cable-lead sensor.
Buy against near-term demand only. If E2B-M18KN10-WP-B1 2M is already on an existing production BOM, secure the units needed for the next build window first, then decide whether to keep it on the line after supply improves.
400Hz sets the speed ceiling, not the sensing quality
400Hz is the clearest electrical limit in the record.
Use it to sort applications, not to oversell them. It supports ordinary presence detect, home position, and moderate-speed indexing, but it does not answer timing margin under small targets, off-axis approach, or metal variation because the listing gives only the headline response frequency and sensing distance. Short version: E2B-M18KN10-WP-B1 2M fits machine sensing jobs, not measurement jobs.
The rest of the fit is mechanical and environmental. The body is nickel-plated brass, the enclosure rating is IP67, and the operating temperature range is -25°C ~ 70°C. Those are useful ceilings for washdown splash, coolant mist, and ordinary plant ambient, but they do not answer chemical compatibility, cable flex life, or hot-zone mounting near drives and motors.
The missing details are the ones that close the review
The constraint is missing interface detail. The listing does not give output current, current consumption, or any wiring pinout beyond PNP-NO, 3-Wire, and that leaves the PLC input match unfinished.
It also omits the mechanical drawing, target requirements, and mounting guidance that usually decide how an unshielded M18 sensor behaves in a crowded bracket. For E2B-M18KN10-WP-B1 2M, those gaps matter more than extra copy because they decide false trips, clearance, and whether the 10mm figure survives the real installation.
View the Win-Source product page for E2B-M18KN10-WP-B1 2M.
Key Takeaways for Engineers & Buyers
- Match the PLC input to PNP-NO, 3-Wire before releasing E2B-M18KN10-WP-B1 2M.
- Reserve E2B-M18KN10-WP-B1 2M only for builds that can use a 10mm unshielded M18 inductive sensor.
- Hold production commits until stock moves above 1 or another approved source is secured.