10V to 30V supply, 16mm sensing distance, M18 threaded body, -25°C to 70°C, IP67
Quick Engineering Summary
| Field | Value |
|---|---|
| Manufacturer | Omron |
| Category | Proximity Sensors - Industrial |
| Package | Bulk |
| Core function | SENSOR PROX INDUCTIVE 16MM CYL |
| Key electrical range | Operating Temperature: -25°C ~ 70°C; Output Type: PNP-NC, 3-Wire; Response Frequency: 400Hz; Voltage - Supply: 10V ~ 30V |
| Reported stock | 1 pcs reported — confirm on RFQ |
Stock is the weak point, not lifecycle
Stock is 1. That's the problem, not lifecycle.
The listing shows Active with no conflict, and EU RoHS compliance supports current use. E2B-M18KN16-M1-B2 fits new design-in only when supply is secured beyond this immediate quantity.
The rail and mount constraints are already set
The numbers set the boundary early: 10V to 30V supply only. That rules out low-voltage logic rails, while the listing still leaves output current unstated.
Then the mechanical fit takes over. A 0.630" (16mm) sensing distance with unshielded construction in a Cylinder, Threaded - M18 body pushes the decision toward bracket geometry and nearby metal, not nominal reach alone. Unshielded mounting is where interchangeable-looking installs often stop being interchangeable.
IP67 and -25°C to 70°C are exposure ceilings for enclosure and ambient conditions. Useful, yes. They still do not settle connector sealing or cable-routing details, because the listing says only Connector.
Would you buy E2B-M18KN16-M1-B2 for a running line?
Would it drop into the line without rework? That's the first question.
Yes, if the machine already expects a PNP-NC, 3-Wire inductive sensor and the layout was built around an M18 threaded barrel with 16mm nominal reach. No, if wiring logic or mounting style is still flexible, because the listed specs narrow the fit more than they seem to at first glance.
This is not a general-purpose answer. E2B-M18KN16-M1-B2 belongs where a normally closed PNP output is intentional, the controller input scheme already matches that logic, and a 400Hz response frequency is enough for the actual mechanism. That 400Hz figure decides whether the sensor can keep up with part presentation and indexing rates under real operating conditions, and if it cannot, the result is missed detection rather than a softer performance loss.
Body and packaging details matter too. Bulk packaging works for maintenance bins or internal machine builds, but it offers no handling advantage for high-mix lines that depend on unitized incoming material. Nickel-plated brass and IP67 suit factory hardware that sees coolant mist, dust, and wrench contact. Short answer: good machine sensor, narrow logic fit.
16mm is useful, but the datasheet still has work to do
16mm is the starting point, not the whole answer.
The missing details are concrete and important: connector pinout, a mechanical drawing for thread length and body geometry, and target-specific sensing detail beyond the nominal 16mm distance. Output current also matters, along with any voltage drop or residual voltage data, because the listing identifies PNP-NC, 3-Wire behavior without showing what load it can drive.
Those gaps decide PLC input compatibility, mounting stack-up, and whether the sensor switches where the machine expects it to.
View the Win-Source product page for E2B-M18KN16-M1-B2.
Key Takeaways for Engineers & Buyers
- Hold E2B-M18KN16-M1-B2 to 10V to 30V rails only; that range decides controller compatibility.
- Use the 16mm sensing distance as the mechanical starting point, then confirm target and mount details from the datasheet.
- Treat stock of 1 as sample-level availability; place production demand only after supply is lined up.